Specifications
Table Of Contents
- Form 150.72-NM1 (908)
- GENERAL SAFETY GUIDELINES
- CHANGEABILITY OF THIS DOCUMENT
- TABLE OF CONTENTS
- LIST OF FIGURES
- LIST OF TABLES
- SECTION 1 – GENERAL CHILLER INFORMATION & SAFETY
- SECTION 2 – PRODUCT DESCRIPTION
- INTRODUCTION
- GENERAL SYSTEM DESCRIPTION
- HIGH AMBIENT KIT
- BUILDING AUTOMATION SYSTEM INTERFACE
- MILLENIUM CONTROL CENTER
- POWER PANEL
- ACCESSORIES AND OPTIONS
- UNIT COMPONENTS
- CONTROL / POWER PANEL COMPONENTS
- PRODUCT IDENTIFICATION NUMBER (PIN)
- BASIC UNIT NOMENCLATURE
- REFRIGERANT FLOW DIAGRAM
- PROCESS AND INSTRUMENTATION DIAGRAM
- SECTION 3 – HANDLING AND STORAGE
- SECTION 4 – INSTALLATION
- INSTALLATION CHECKLIST
- HANDLING
- INSPECTION
- LOCATION AND CLEARANCES
- SPRING ISOLATORS (OPTIONAL)
- COMPRESSOR MOUNTING
- REMOTE COOLER OPTION
- CHILLED LIQUID PIPING
- PIPEWORK ARRANGEMENT
- DUCT WORK CONNECTION
- WIRING
- COMPRESSOR HEATERS
- RELIEF VALVES
- HIGH PRESSURE CUTOUT
- SINGLE-POINT SUPPLY CONNECTION – TERMINAL BLOCK, NON-FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER
- USER CONTROL WIRING INPUTS
- USER CONTROL WIRING OUTPUTS
- SECTION 5 – TECHNICAL DATA
- OPERATIONAL LIMITATIONS (ENGLISH)
- HEAT EXCHANGER FLOW, GPM
- PHYSICAL DATA (ENGLISH)
- ELECTRICAL DATA
- ELECTRICAL NOTES
- ELECTRICAL DATA W/O PUMPS
- ELECTRICAL DATA W/ PUMPS
- ELECTRICAL NOTES AND LEGEND
- WIRING DIAGRAMS
- DIMENSIONS (ENGLISH)
- TECHNICAL DATA – CLEARANCES
- WEIGHT DISTRIBUTION AND ISOLATOR MOUNTING POSITIONS
- ISOLATOR INFORMATION FOR UNITS SHIPPED ON OR AFTER JUNE 15, 2008
- ISOLATOR INFORMATION FOR UNITS SHIPPED BEFORE JUNE 15, 2008
- SLRS Seismic Isolator Specifications
- SLRS Seismic Isolator Installation and Adjustment
- One Inch Deflection Spring Isolator Cross-reference
- Installation of 1” Deflection Mounts
- Neoprene Isolator Cross-reference
- Two Inch Deflection, Seismic Spring IsolatorCross-reference - SLRS
- SLRS Seismic Isolator Installation and Adjustment
- SECTION 6 – COMMISSIONING
- SECTION 7 – UNIT CONTROLS
- SECTION 8 – UNIT OPERATION
- CAPACITY CONTROL
- SUCTION PRESSURE LIMIT CONTROLS
- DISCHARGE PRESSURE LIMIT CONTROLS
- LEAVING CHILLED LIQUID CONTROL
- LEAVING CHILLED LIQUID CONTROLOVERRIDE TO REDUCE CYCLING
- LEAVING CHILLED LIQUID SYSTEM LEAD/LAG AND COMPRESSOR SEQUENCING
- RETURN CHILLED LIQUID CONTROL
- RETURN CHILLLED LIQUID SYSTEM LEAD/LAG AND COMPRESSOR SEQUENCING
- ANTI-RECYCLE TIMER
- ANTI-COINCIDENCE TIMER
- EVAPORATOR PUMP CONTROL & YORK HYDRO KIT PUMP CONTROL
- EVAPORATOR HEATER CONTROL
- PUMPDOWN CONTROL
- STANDARD CONDENSER FAN CONTROL
- LOAD LIMITING
- COMPRESSOR RUN STATUS
- ALARM STATUS
- REMOTE BAS/EMS TEMPERATURE RESET USINGA VOLTAGE OR CURRENT SIGNAL
- SECTION 9 – SERVICE AND TROUBLESHOOTING
- SECTION 10 – MAINTENANCE
FORM 150.72-NM1 (908)
27
JOHNSON CONTROLS
2
PRODUCT IDENTIFICATION NUMBER (PIN) (CON’T)
FEATURE DESCRIPTION OPTION DESCRIPTION
RDOUT READOUT KITS (PIN 23) B
BOTH DISCHARGE & SUCTION PRESSURE TRANSDUCER
READOUT REQUIRED
Q SPECIAL PRESSURE READOUT REQUIRED
SAFETY SAFETY CODES (PIN 24) L N AMERICAN SAFETY CODE (CUL/CETL)
C EUROPEAN SAFTEY CODE ( CE )
SENSOR PIN 25 X X
Q SPECIAL QUOTE
PUMP PIN 26 C MOTOR CURRENT MODULE
Q SPECIAL QUOTE
REMOTE REMOTE PANEL (PIN 27) X NO REMOTE PANEL REQUIRED
O OPIVIEW REMOTE PANEL REQUIRED
Q SPECIAL REMOTE PANEL REQUIRED
SEQ SEQUENCE KIT (PIN 28) X NO SEQUENCE KIT REQUIRED
S SEQUENCE KIT REQUIRED= {SEQ/S}
Q SPECIAL SEQUENCE KIT REQUIRED
TEMP LEAVING WATER TEMP(29,30) NUM LEAVING WATER TEMP = {TEMP/NUM} DEGREES
QQ SPECIAL LWT REQUIREMENTS
CHICAGO CHICAGO CODE KIT (PIN 31) X NO CHICAGO CODE KIT REQUIRED
C CHICAGO CODE KIT REQUIRED
S SERVICE ISOLATION VALVES
B BOTH CHICAGO CODE & SERV ISOLATION
Q SPECIAL CHICAGO CODE KIT REQUIRED
VALVES VALVES (PIN 32) X STANDARD VALVES REQ’D
Q SPECIAL OPTIONAL VALVES REQ’D
HGBP HOT GAS BYPASS (PIN 33) X NO HOT GAS BYPASS REQUIRED
1 HOT GAS BYPASS REQUIRED - 1 CIRCUIT
Q SPECIAL HOT GAS BYPASS REQUIRED
GAUGE PIN 34 X X
Q SPECIAL QUOTE
OVERLOAD PIN 35 X X
Q SPECIAL QUOTE
PIN36 PIN 36 X X
Q SPECIAL QUOTE
HTR
CRANKCASE HEATER (PIN
37)
H CRANKCASE HEATER STANDARD
Q SPECIAL CRANKCASE HEATER REQUIRED
DWP DWP (PIN 38) X 150PSIG DWP WATERSIDE
3 300PSIG DWP WATERSIDE
INS INSULATION (PIN 39) X STANDARD INSULATION
D DOUBLE THICK INSULATION
Q SPECIAL INSULATION REQUIRED
FLANGES FLANGES (PIN 40) X NO FLANGES REQUIRED
V VICTAULIC FLANGES REQUIRED
Q SPECIAL FLANGES REQUIRED