Installation & Owner’s Manual MINISPLIT HIGH WALL MODELS RLCA-RLHA 07-30 RLCB-RLHB 07-28 RACC-RAHC 07-28 AIR CONDITIONER The units comply with one or more of the following marks - see unit for details. J277-EN.
CONTENTS Safety Precautions ...................................................... 3 Part Names ................................................................... 4 Manual Operation ........................................................ 5 How the air conditioner works ................................... 5 Optimal operation ........................................................ 6 Preparation Before Installation .................................. 6 Installation Procedure .................................
REQUIRED TOOLS 1. 2. 3. 4. 5. 6. 7. 8. Screw driver Hexagonal wrench Torque wrench Spanner Reamer Hole core drill Tape measure Thermometer 9. 10. 11. 12. 13. 14. 15. EXTENDED PARTS Manifold gauge Gas leak detector Vacuum pump Pipe clamp Pipe cutter Flare tool set Electrical circuit tester 1. Refrigerant Pipe Models Liquid size Gas size 07-09 1/4 inch 3/8 inch 12-18 1/4 inch 1/2 inch 24-30 3/8 inch 5/8 inch 2. Pipe insulation material (Polyethylene foam 9 mm thick) 3. Vinyl tape 4.
PART NAMES INDOOR UNIT ■ INDOOR & OUTDOOR UNIT 1 2 3 4 5 6 7 Front panel Air inlet Air filter Air outlet Horizontal air flow grille Vertical air flow louver Display panel 8 Remote controller signal 9 0 = ~ receiver Remote controller Manual control button Connecting pipe, drain hose Air inlet (side and rear) Air outlet ■ DISPLAY PANEL 1 AUTO indicator This indicator illuminates when the air conditioner is in AUTO operation.
MANUAL OPERATION Manual operation can be used temporarily in case you can not find the remote controller or its batteries are exhausted. 1 Open and lift the front panel up to an angle at which it remains fixed with a clicking sound. 2 Press the button until the AUTO indicator is lit, the unit will work in forced AUTO mode. 3 Close the panel firmly to its original position. Panel CAUTIONS • Once you push the manual button, the operation mode is shifted in an order as: AUTO, COOL, OFF.
OPTIMAL OPERATION To achieve optimal performance, Please note the following: • Adjust the air flow direction correctly so that it is not directed on people. • Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive temperature levels. • Close doors and windows on COOL or HEAT modes, or performance may be reduced. • Use TIMER ON button on the remote controller to select a time you want to start your air conditioner.
OUTDOOR UNIT PICTURES RLDB-RLJB 18 RLDA-RLJA 07-09, RLDB-RLJB 07-09, RADC-RAJC 07 88 750 285 225 540 525 404 261 82 60 590 75 80 60 700 62 250 290 458 88 33 5 530 110 35 RLDA-RLJA 24-30, RLDB-RLJB 24-28, RADC-RAJC 18-28 RLDA-RLJA 12-18, RLDB-RLJB 12, RADC-RAJC 09-12 128 843 245 313 301.5 5 EN 298 135 351.2 272 694.5 540 527 Ø420 780 548 45 115 335 266 90 125 10 560.1 235 141.5 48 ENGLISH J277-EN.indd 7 7 26.12.
PARTS INSTALLATION Number Name of part 3 Q’ty Installation plate 1 2 Clip anchor 8 3 Self-tapping screw A ST3.9X25 8 12c mm 2 inim um 15cm minim um 1 1 Liquid side ø 6.35 4 Connecting pipe assembly Gas side ø 9.53 (<12000Btu/h model) ø 12.7 (21000Btu/h model > Cooling capacity f 12000Btu/h model) Parts you must purchase 12cm min imum ø 16 (f21000Btu/h model) 5 Remote controller 6 Self-tapping screw B ST3.
MODEL 24-30 Above 150mm from the ceiling Hooked Part Hooked Part Hooked Part 1080 108 432 22 432 Above 120mm from the wall A Right 95 115 Pipe hole 50 58 95 50 58 330 Above 120mm from the wall 115 465 465 B Right Pipe hole Indoor Unit Outline D Right F Left C Right CAUTION • Be careful when handling the sharp edge of the mounting plate. ■ Wiring • This indoor unit is ready for connection to the outdoor unit.
■ Indoor Unit Fixing • • • • Thread the indoor unit piping and cable through the hole. Hang the top of the unit onto the upper ridge of them in mounting plate. Make sure that the unit is correctly hung in place by sliding it to the left, then to the right. Press the bottom left and bottom right hand corners of the unit against the mounting plate until the fixing prongs click into place in the retainers provided to that effect.
To this effect, when the piping has been evacuated, close the pressure gauge tap, note the value on the gauge, then wait for 15 minutes. If the needle moves, there is a leak in the system. Make the necessary adjustments or repairs and repeat this procedure until the needle no longer moves. • Open the service valves and top up the refrigerant charge if necessary.
■ Wiring Prepare the power source for exclusive with the air conditioner. The supply voltage must comply with the rated voltage of the air conditioner: The plug socket shall be accessible after installation. Remark: All the wiring must be based on the wiring nameplate which is shown on the model. CAUTIONS • Perform the wiring with sufficient capacity. Installation places legally require a short circuit isolator to be attached to prevent electrical shock. • Do not extend the power cable code by cutting.
■ Wiring Connection Models : 07-18 Indoor Outdoor Terminal block of indoor unit Terminal block of outdoor unit 1 2(N) 3 4 1 2(N) 3 4 1 2(N) 1 2(N) 3 4 Cord clamp To outdoor unit To outdoor unit Cooling only type Cooling & heating type Models : 24-30 Indoor Cooling only type Cooling & heating type Outdoor Terminal block of indoor unit 1 2 (N) Wire-holding board Ter S Terminal block of outdoor unit 1 2(N) S L Term 12 N Cord clamp Cooling only type / cooling & heating type Cool
■ Electrical Work Model Power Source Switch and Fuse rating Wiring size 10A f 1.0 mm2 16A f 1.5 mm2 220-240V ~ 50Hz 7000-9000 Btu/h 220-230V ~ 60Hz 220-240V ~50Hz 12000 Btu/h 220-230V ~ 60Hz 220-240V ~50Hz 18000 Btu/h 25A 220-230V ~ 60Hz f 2.5 mm2 220-240V ~50Hz 24000-30000 Btu/h 32A 220-230V ~ 60Hz NOTE NOTE The supply volyage must be consistent with the rate voltage of the air conditioner. ■ Defrosting operation (Available for heating only) 1.
MAINTENANCE WARNING Household Drain Cleaner It is necessary to stop the air conditioner and disconnect the power supply before cleaning. No ■ Cleaning the indoor unit and remote controller CAUTION Thinner • Use a dry cloth to wipe the indoor unit and remote controller. • A cloth dampened with cold water may be used on the indoor unit if it is very dirty. • The front panel of the indoor unit can be removed and cleaned with water. Then wipe it with a dry cloth.
OPERATION TIPS The following events may occur during normal operation. 1. Protection of the air conditioner. Compressor protection • The compressor can not restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) • The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached. A) When heating has just starting. B) Defrosting. C) Low temperature heating.
TROUBLESHOOTING GUIDE Problem Probable cause Remedy A. The air conditioner does not run. 1. 2. 3. 4. 5. 6. Power failure. Fuse blown or circuit breaker open. Voltage is too low. Faulty contactor or relay. Electrical connections loose. Thermostat adjustment too low (in heating mode) or too high (in cooling mode). 7. Faulty capacitor. 8. Incorrect wiring, terminal loose. 9. Pressure switch tripped. 1. Wait for power resume. 2. Replace the fuse or reset the breaker. 3. Find the cause and fix it. 4.
TECHNICAL SPECIFICATIONS Technical Specifications : Everest RLCA-RLHA “R22” -50Hz Indoor Unit Models RLEA-RLKA RLEA07 RLKA07 RLEA09 RLKA09 RLEA12 RLKA12 RLEA18 RLKA18 RLEA24 RLKA24 RLEA28 RLKA28 RLDA-RLJA Outdoor Unit RLDA07 RLJA07 RLDA09 RLJA09 RLDA12 RLJA12 RLDA18 RLJA18 RLDA24 RLJA24 RLDA28 RLJA28 V/Ph/Hz Power Supply 220-240/1/50 Ph Power Consumption Running Current 1 1 1 1 0.8 1.01 1.01 1.35 1.35 1.96 1.96 2.8 2.8 3.25 3.25/3.36 A 3.5 3.5 4.6 4.6 6.0 6.0 9.4 9.4 12.
TECHNICAL SPECIFICATIONS Technical Specifications : Everest RLCA-RLHA “R22” -60Hz Indoor Unit Models RLEA-RLKA RLEA07 RLKA07 RLEA09 RLKA09 RLEA12 RLKA12 RLEA18 RLKA18 RLEA24 RLKA24 RLEA30 RLKA30 RLDA-RLJA Outdoor Unit RLDA07 RLJA07 RLDA09 RLJA09 RLDA12 RLJA12 RLDA18 RLJA18 RLDA24 RLJA24 RLDA30 RLJA30 V/Ph/Hz Power Supply 220-230/1/60 Ph Power Consumption Running Current 1 1 1 1 0.71 0.95 0.95 1.21 1.21 1.95 1.95 2.67 2.67 3.4 3.4/3.4 A 3.2 3.2 4.5 4.5 5.5 5.5 8.9 8.9 12.
TECHNICAL SPECIFICATIONS Technical Specifications : Everest RLCB-RLHB “R407C” -50Hz Indoor Unit Models RLEB-RLKB RLEB07 RLKB07 RLEB09 RLKB09 RLEB12 RLKB12 RLEB18 RLKB18 RLEB24 RLKB24 RLEB28 RLKB28 RLDB-RLJB Outdoor Unit RLDB07 RLJB07 RLDB09 RLJB09 RLDB12 RLJB12 RLDB18 RLJB18 RLDB24 RLJB24 RLDB28 RLJB28 V/Ph/Hz Power Supply 220-240/1/50 Ph Power Consumption Running Current 1 1 1 1 0.78 1 1 1.35 1.35 1.96 1.96 2.73 2.73 3.05 3.05/3.20 A 3.5 3.5 4.4 4.4 6.0 6.0 9.4 9.4 12.
TECHNICAL SPECIFICATIONS Technical Specifications : Everest RACC-RAHC “R410A” -50Hz Indoor Unit Models RAEC-RAKC RAEC07 RAKC07 RAEC09 RAKC09 RAEC12 RAKC12 RAEC18 RAKC18 RAEC24 RAKC24 RAEC28 RAKC28 RADC-RAJC Outdoor Unit RADC07 RAJC07 RADC09 RAJC09 RADC12 RAJC12 RADC18 RAJC18 RADC24 RAJC24 RADC28 RAJC28 V/Ph/Hz Power Supply 220-240/1/50 Ph Power Consumption Running Current 1 1 1 1 0.64 0.82 0.82 1.12 1.12 1.72 1.72 2.53 2.53 2.60 2.60/2.68 A 2.8 2.8 3.6 3.6 5.0 5.0 7.8 7.
DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY Type of Equipment Brand Name Type Designation Application of Council Directive (s) Air Conditioners YORK HAEA-HADA07/09/12FS, HAEB-HADB07/09/12FS, HAEC-HADC07/09/12FS, HAKA-HAJA07/09/12FS, HAKB-HAJB07/09/12FS, HAKC-HAJC07/09/12FS, HEEB-HEDB07/09/12/18/24/30FS, HEKB-HEJB07/09/12/18/21/24/30FS, HLEA-HLDA07/09/12/18/24FS, HLCA-HLHA24/28/FS, HMEA09MC/MD/ME, HMDA18MC, HMDA21MD, HMDA27ME, HMKB09MC/MD/ME/MF, HMKB12MD/MF, HMJB18MC, HMJB21MD, HMJB27ME, HMJB30MF,