Technical Guide

5146416-YTG-A-0815
10 Johnson Controls Unitary Products
— = Not Applicable.
MP Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
YCD24B21(H,S) CF42B 17.5 600 - 1000 800 24.0 17.6 13.00 11.25
YCD30B21(H,S) CF/CM/CU30B 17.5 800 - 1200 1000 29.0 21.2 13.00 11.00
YCD30B21(H,S) CF/CM/CU30C 21.0 800 - 1200 1000 29.0 21.2 13.00 11.00
YCD30B21(H,S) CF/CM/CU30D 24.5 800 - 1200 1000 29.0 21.2 13.00 11.00
YCD30B21(H,S) CF/CM/CU36B 17.5 800 - 1200 1000 29.8 21.8 13.00 11.00
YCD30B21(H,S) CF/CM/CU36C 21.0 800 - 1200 1000 29.8 21.8 13.00 11.00
YCD30B21(H,S) CF/CM/CU36D 24.5 800 - 1200 1000 29.8 21.8 13.00 11.00
YCD30B21(H,S) CF/CM/CU42C 21.0 800 - 1200 1000 29.8 21.6 13.00 11.00
YCD30B21(H,S) CF/CM/CU42D 24.5 800 - 1200 1000 29.8 21.6 13.00 11.00
YCD30B21(H,S) CF42B 17.5 800 - 1200 1000 29.8 21.6 13.00 11.00
YCD36B21(H,S) CF/CM/CU36B 17.5 1000 - 1400 1200 34.4 25.0 13.00 11.00
YCD36B21(H,S) CF/CM/CU36C 21.0 1000 - 1400 1200 34.4 25.0 13.00 11.00
YCD36B21(H,S) CF/CM/CU36D 24.5 1000 - 1400 1200 34.4 25.0 13.00 11.00
YCD36B21(H,S) CF/CM/CU42C 21.0 1000 - 1400 1200 35.2 25.6 13.00 11.00
YCD36B21(H,S) CF/CM/CU42D 24.5 1000 - 1400 1200 35.2 25.6 13.00 11.00
YCD36B21(H,S) CF/CM/CU48C 21.0 1000 - 1400 1200 35.2 25.4 13.00 11.00
YCD36B21(H,S) CF/CM/CU48D 24.5 1000 - 1400 1200 35.2 25.4 13.00 11.00
YCD36B21(H,S) CF42B 17.5 1000 - 1400 1200 35.2 25.6 13.00 11.00
YCD42B21(H,S) CF/CM/CU42C 21.0 1200 - 1600 1400 41.0 30.5 13.00 11.00
YCD42B21(H,S) CF/CM/CU42D 24.5 1200 - 1600 1400 41.0 30.5 13.00 11.00
YCD42B21(H,S) CF/CM/CU48C 21.0 1200 - 1600 1400 42.0 31.0 13.00 11.00
YCD42B21(H,S) CF/CM/CU48D 24.5 1200 - 1600 1400 42.0 31.0 13.00 11.00
YCD42B21(H,S) CF/CM/CU60C 21.0 1200 - 1600 1400 42.0 31.0 13.00 11.00
YCD42B21(H,S) CF/CM/CU60D 24.5 1200 - 1600 1400 42.0 31.0 13.00 11.00
YCD42B21(H,S) CF/CM64D 24.5 1200 - 1600 1400 42.0 31.0 13.00 11.25
YCD42B21(H,S) CF42B 17.5 1200 - 1600 1225 40.0 28.0 13.00 11.00
YCD48B21S CF/CM/CU48C 21.0 1400 - 1800 1600 46.0 33.5 13.00 11.00
YCD48B21S CF/CM/CU48D 24.5 1400 - 1800 1600 46.0 33.5 13.00 11.00
YCD48B21S CF/CM/CU60C 21.0 1400 - 1800 1600 48.0 36.0 13.00 11.25
YCD48B21S CF/CM/CU60D 24.5 1400 - 1800 1600 48.0 36.0 13.00 11.25
YCD48B21S CF/CM64D 24.5 1400 - 1800 1600 48.0 36.0 13.00 11.25
YCD60B21S CF/CM/CU60C 21.0 1520 - 1920 1720 55.0 40.0 13.00 11.00
YCD60B21S CF/CM/CU60D 24.5 1520 - 1920 1725 55.0 40.0 13.00 11.00
YCD60B21S CF/CM64D 24.5 1520 - 1920 1725 56.5 41.0 13.00 11.00
For rated condition information, see the footnotes below the System Capacity - Single Piece and Modular Air Handlers table.
1. Requires a S1-2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings) (Continued)
UNIT MODEL
COIL
CFM RANGE
(MIN.-MAX.)
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER
1
EER
TOTAL SENS.