Technical Guide

251933-YTG-V-0913
46 Johnson Controls Unitary Products
115°F 125°F
1250
77 57.6 6.0 22.6 19.5 14.5 - - - 53.6 6.6 20.0 18.3 13.4 - - -
72 52.7 5.9 32.7 27.7 22.6 17.6 - - 48.5 6.5 31.0 26.0 21.1 16.2 - -
67 47.7 5.9 42.9 35.8 30.8 25.7 20.7 - 43.5 6.5 41.7 33.8 28.8 23.9 19.0 -
62 44.7 5.9 44.7 44.7 36.6 31.6 26.5 21.5 41.4 6.4 41.4 41.4 33.4 28.5 23.6 18.7
1500
77 59.0 6.0 27.6 21.8 16.0 - - - 54.8 6.6 26.2 20.5 14.8 - - -
72 53.9 6.0 36.6 30.8 25.0 19.1 - - 49.6 6.5 34.8 29.1 23.4 17.7 - -
67 48.8 5.9 45.6 39.8 33.9 28.1 22.3 - 44.4 6.5 43.3 37.6 31.9 26.2 20.5 -
62 45.8 5.9 45.8 45.8 40.4 34.5 28.7 22.9 42.3 6.5 42.3 42.3 37.0 31.3 25.6 19.9
57 45.8 5.9 45.8 45.8 40.4 34.6 28.8 22.9 42.6 6.4 42.6 42.6 37.2 31.5 25.8 20.1
1750
77 60.3 6.0 32.7 24.1 17.5 - - - 56.0 6.6 32.4 22.7 16.2 - - -
72 55.1 6.0 40.5 33.9 27.3 20.7 - - 50.6 6.6 38.6 32.1 25.6 19.1 - -
67 50.0 5.9 48.3 43.7 37.1 30.5 23.8 - 45.3 6.5 45.0 41.5 35.0 28.5 22.0 -
62 46.8 5.9 46.8 46.8 44.1 37.5 30.9 24.2 43.2 6.5 43.2 43.2 40.5 34.1 27.6 21.1
57 46.9 5.9 46.9 46.9 44.2 37.6 30.9 24.3 43.5 6.5 43.5 43.5 40.8 34.3 27.8 21.3
2000
77 61.7 6.0 37.8 26.4 18.9 - - - 57.1 6.6 38.6 24.9 17.7 - - -
72 56.4 6.0 44.4 37.0 29.6 22.2 - - 51.7 6.6 42.4 35.1 27.9 20.6 - -
67 51.1 5.9 51.1 47.7 40.2 32.8 25.4 - 46.2 6.5 46.2 45.3 38.1 30.8 23.5 -
62 47.8 5.9 47.8 47.8 47.8 40.4 33.0 25.6 44.1 6.5 44.1 44.1 44.1 36.8 29.6 22.3
57 47.9 5.9 47.9 47.9 47.9 40.5 33.1 25.7 44.4 6.5 44.4 44.4 44.4 37.1 29.8 22.6
2250
72 57.1 6.0 48.1 40.0 31.9 23.8 - - 52.4 6.6 46.5 38.5 30.4 22.3 - -
67 51.7 5.9 51.7 50.0 43.4 35.3 27.2 - 46.9 6.5 46.9 46.9 41.5 33.4 25.3 -
62 48.4 5.9 48.4 48.4 48.4 40.4 32.3 24.2 44.7 6.5 44.7 44.7 44.7 36.6 28.6 20.5
57 48.5 5.9 48.5 48.5 48.5 40.5 32.4 24.3 45.0 6.5 45.0 45.0 45.0 36.9 28.8 20.8
2500
72 57.7 6.0 51.7 43.0 34.2 25.5 - - 53.1 6.6 50.6 41.8 32.9 24.0 - -
67 52.3 5.9 52.3 52.3 46.5 37.8 29.0 - 47.5 6.5 47.5 47.5 44.9 36.0 27.2 -
62 49.0 5.9 49.0 49.0 49.0 40.3 31.5 22.8 45.3 6.5 45.3 45.3 45.3 36.4 27.6 18.7
57 49.1 5.9 49.1 49.1 49.1 40.4 31.6 22.9 45.6 6.5 45.6 45.6 45.6 36.7 27.8 19.0
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
XP060 (5.0 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F) Return Dry Bulb (°F)
90 85 80 75 70 65 90 85 80 75 70 65