Technical Guide

251933-YTG-V-0913
88 Johnson Controls Unitary Products
060
(5.0)
208-3-60
14.1 88.0 22.0 2.3 8.2 10.0
None - - - 38.1 50
E05 4.0 1 11.1 38.1 50
E07 5.6 1 15.5 42.2 50
E10 8.0 1 22.2 50.5 60
E15 11.9 2 33.0 64.0 70
E20 15.9 2 44.1 77.9 80
E30 22.2 2 61.6 99.8 100
230-3-60
14.1 88.0 22.0 2.3 8.2 10.0
None - - - 38.1 50
E05 5.3 1 12.7 38.7 50
E07 7.5 1 18.0 45.3 50
E10 10.6 1 25.5 54.6 60
E15 15.9 2 38.2 70.6 80
E20 21.2 2 51.0 86.5 90
E30 29.6 2 71.2 111.8 125
460-3-60
7.7 55.0 12.0 1.3 4.1 5.0
None - - - 20.0 25
E07 6.8 1 8.2 21.6 25
E10 10.1 1 12.1 26.6 30
E15 13.6 2 16.4 31.8 35
E20 19.5 2 23.5 40.7 45
E30 28.8 2 34.6 54.7 60
575-3-60
4.8 36.0 7.5 1.3 3.6 4.0
None - - - 14.6 15
E10 10.6 1 10.2 22.2 25
E15 15.9 1 15.3 28.6 30
E20 21.2 2 20.4 35.0 35
E30 30.4 2 29.3 46.1 50
1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.
ZF036-060 (Belt Drive High Static) (Continued)
Size
(Tons)
Volt
Compressors
(each)
OD Fan
Motors
(each)
Supply
Blower
Motor
Pwr
Conv
Outlet
Electric Heat Option
MCA
1
(Amps)
Max Fuse
2
/
Breaker
3
Size
(Amps)
RLA LRA MCC FLA FLA FLA Model kW Stages Amps