3. Tighten motor set screw. Check the strength of this connection (pre-tightened at
factory) by holding the motor housing in position and turning the downrod counter
clockwise. If this connection slips, retighten motor setscrew and locknut. Follow the
same procedures as mentioned above for downrod setscrew.
4. Install ball into hanger bracket opening. The tab opposite of the hanger bracket
opening should fit in slot on ball (Fig 9) .
WARNING: Do not force connector pin through downrod. Use of force could cause
damage to wires inside. Make sure the stop pin is properly engaged to prevent it from
falling out.
2 Tighten downrod setscrew. Some models have a locknut for the setscrew. To insure
the setscrew fully seats against the downrod. It is necessary to back off the locknut
until it contact the setscrew head prior to tightened the setscrew. When setscrew is
tightened against downrod.locknut should then be tightened against connector yoke.
Some models have 2 downrod s
etscrews. Repeat for both (Fig.8)
5. Make wire connections (refer to section titled” Electrical Connections”) For
cUL-listed fan, please secure the safety cable to the junction box.
6. Slide canopy up, and fasten to hanger bracket with the 4 screws provided.
WARNING: To avoid damaging the blade arms and blades, do not install either until
fan is fastened to ceiling. To avoid motor shift, handle fan by downrod or switch
housing only.