Instructions / Assembly
Page 9 of 11
9. Typical installations.
Installation # 1 Installation #2 Installation #3
FIREPLACE INSERT INSTALLATION
1) Prepare the chimney flue opening using best practice following all codes & standards having
jurisdiction.
2) Connect the Insert Connector by tightening up on gear clamp around liner in place of the Lock N
Go Tee in step 3 above.
3) Attach the prepared nose cone to the Connector and guide the liner down the chimney into the
fireplace opening.
4) Remove the nose cone and fully insert the Insert Connector in the flue opening of the fireplace
insert.
5) Secure the Insert Connector in the fireplace insert using appropriate fastener to the flue outlet collar
and by bending back the tabs to the underside of fireplace insert.
Note to installer: If there is no collar present on the outlet of the fireplace insert for the Insert
Connector to fasten onto, bend the tabs of the Insert Connector back to the underside of fireplace
insert fire chamber and affix using best practice method and/or approved cement.
6) Insert can now be set into place pulling the liner slack up through chimney.
7) Continue on from Step 8 above to finish off.