User guide
PIR MOTION DETECTOR MOUNTING
Use adhesive tape to mount PIR motion detector at 2
meters above surface.
To enhance proper operation, place PIR motion detector
on the angle which can detect the room widely. The solid
area means the detector’s coverage range.
DOOR/WINDOW SENSOR MOUNTING
Use the screws or adhesive tape to fix the rear cover on
the frame along the opening edge of door / window.
Fix the Magnet by using the adhesive tape or fixing
screws, locate the Magnet close to the sensor.
The distance between these two devices should be less
than 1.9cm. The magnet should not be more than 8mm
from the detector when the door is closed.
If difficulty is experienced fitting the door/window
contact because of space etc, the multiple door/window
contact set should be used (not included). The magnet/
contact pairs are wired using bell wire (not supplied) to
the extension terminals. The knockout in the top of the
door/window contact must be removed to allow the wire
to pass through. The total length of wire used must not
exceed 10 meters. The magnet/contact pairs should be
no further than 8mm apart. It is possible to use a single
pair of multiple door/window contacts with a detector if
you experience problems fitting the main unit to the door
frame. When using multiple switches on a door/window
contact, you can use the detector without having a magnet
alongside the main unit.