User guide
Heating inputs - special (level input) devices for manually
setting desired heating point of virtual zone. For example,
with mounted thermostat which support common
communication protocols (ZigBee, Z-wave, etc.) set
temperature point in which heating will turn On/Off.
Cooling outputs - used for controlling cooling devices,
air conditions and etc. by using actuators. For example, if
you like to control radiator you can use battery powered
thermostatic valve, with built in wireless module for com-
munication with Zipabox, or you can use regular thermo-
static valve powered by electrical current and use actua-
tor switches which are able to communicate with Zibabox
and control those valves. Here you can choose devices
like actuators or electrical valves, or virtual devices (e.g.
Infra-Red codes which can turn on/off your cooling body)
which you would like to include to virtual zone/room.
Cooling inputs - special (level input) devices for manually
setting desired heating point of virtual zone. For example,
with mounted thermostat which support common
communication protocols (ZigBee, Z-wave, etc.) set
temperature point in which heating will turn On/Off.
Thermometers - used for acquiring information about
current room/zone temperature from one or more
thermometers.
FUNCTION
Function is divided in four groups:
LAST - user can use last value provided by any
thermometer as the current temperature where
battery operated thermometers are sending info about
temperature occasionally (energy saving).
AVARAGE - average thermometers are calibrated
differently, most precise value would be average
number of all the values received from the
thermometers within one room
HIGH - uses highest temperature value sent from any
temperature meter
LOW - uses lowest temperature sent from any
temperature meter
USING AND MODIFYING CLIMATE WIDGET
When new climate is created it will show up in Climate
widget. From here climate can be easily controlled and
modified.
Climate can be used for manual or automatically
temperature control.
MANUAL CONTROL
Manual temperature adjustment can be done by moving
slider left or right and clicking heating, cooling, auto or
off button. Picture below explains how slider is divided on
colling, heating and set_tolerance.
AUTO - desired temperature is set trough adjustment
of set_point temperature by moving heating slider
right or cooling slider left.
HEATING heating is modified by moving slider left or
right.
COOLING cooling is modified by moving slider left or
right.
46