User manual
STAIRCASE LIGHTING TIMER ASM-10 INSTRUCTION MANUAL
FEATURES
TECHNICAL PARAMETERS
DESCRIPTION
APPEARANCE
ver. 0.4.2 _ 2006.06.19_13:00
ASM - 10
Supply cables: L (black), N (blue)
Variable voltage supply: 230 V~
Supply voltage tolerance: from -15 to +10 %
Nominal frequency: 50 / 60 Hz
Variable power consumption: 41 mA
Power supply indicator: LED green
Dim up time setting (t
1
): from 0 to 10 s (rotary potentiometer)
Operating time setting (t
2
): from 0 to 10 min (rotary potentiometer)
Dim down time setting (t
3
): from 0 to 60 s (rotary potentiometer)
Lighting level adjustment when blocking is switched on (L):
10 ÷ 100 %
Receiver power supply indicator: dioda LED red
Charging power: 30 ÷ 600 W
Controlling element:
triac 600 VA (clamps N, )
Number of switch cables:
11
Diameter of connecting cables:
from 0,2 to 2,50 mm
2
Operating temperature:
from -20 to +45
o
C
Operating position:
freely
Assembly:
rail TH35 (PN-EN 60715)
Protection level of casing:
IP20 (PN-EN 60529)
Protection level:
II
Over voltage category:
II
Pollution:
2
Electric strength:
1 kV (PN-EN 61000-4-5)
Dimensions (height / width / depth):
doublemodule (35 mm) 90x35x66 mm
Weight:
130 g
Compatible with standards: PN-EN 60669-1; PN-EN 60669-2-1
PN-EN 61000-4-2,3,4,5,6,11
ی Intelligentlightingcontrol,
ی lightingtimeadjustment,
ی switchontimeadjustment,
ی blankingtimeadjustment,
ی lightingleveladjustmentincasesthe
pushbutton is blocked,
ی inputratedindicator,
ی doublemodulecasing,
ی TH-35DINrailinstallation.
The staircase lighting time delay
switch ASM-10 is used to control lighting
devices on staircases and corridors.
After releasing the system it switches
on the lighting with fluent brightening.
The lighting is switched on by t
2
time
and followed by fluent blanking. The
system is equipped with intelligent anti
blocking function where you can preset
the lighting blanking level in cases the
pushbutton is blocked.
Zakład Mechaniki i Elektroniki
ZAMEL sp.j.
J.W.Dzida,K.Łodzińska
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamel.pl, e-mail: marketing@zamel.pl
The device is desig-
ned for one-phase in-
stallation and must be
installed in accordance
with standards valid in a
particular country. The
device should be con-
nected according to the details included
in this operating manual. Installation,
connection and control should be car-
ried out by a qualied electrician staff,
who act in accordance with the service
manual and the device functions. Disas-
sembling of the device is equal with a
loss of guarantee and can cause electric
shock. Before installation make sure the
connection cables are not under voltage.
The cruciform head screwdriver 3,5 mm
should be used to instal the device. Im-
proper transport, storage, and use of the
deviceinuenceitswrongfunctioning.It
is not advisable to instal the device in
the following cases: if any device part is
missing or the device is damaged or de-
formed. In case of improper functioning
of the device contact the producer.
CAUTION
output clamps (N, )
supply voltage terminal (L)
light intensity adjusting
range (L)
operating time adjusting
range (t
2
)
relay indicator light
supply voltage terminal (N)
input terminals of the
release system
supply indicator light
dim up time adjusting
range (t
1
)
dim down time
adjusting range (t
3
)