User manual
DIP-01, DIP-02 DIMMER
INSTRUCTION MANUAL
Zakład Mechaniki i Elektroniki
ZAMEL sp.j.
J.W. Dzida, K. Łodzińska
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: marketing@zamel.pl
APPERANCE
FEATURES
DESCRIPTION
ی Incandescent lights intensity control,
ی Easy applicable together with any
existing electrical system,
ی Applicable together with single pole
push buttons, illuminated,
ی Maximum output power: 350 W,
ی Model with the light intensity storage
available (DIP-02),
ی Device triggering by means of the L
wire,
ی Series connection with a light source,
ی Casing designed for mounting in a
junction box.
The DIP-01, DIP-02 dimmers are designed
for incandescent lights intensity adjust-
ment. It is possible to control light intensity
by means of a single pole push button. If
needed, it is possible to connect the push
buttons in parallel. The devices are capa-
ble of switching ON and OFF the light, and
fluent brightening up and dimming. The
dimmers are designed for mounting in a
junction box. By means of the dimmers
It is possible to control lighting systems in
a comfortable, convenient and economical
way. Additionally, the DIP-02 model is ca-
pable of storing light intensity level.
TECHNICAL DATA
DIP - 01 DIP - 02
Power terminals: L(black), brown - in series with load
Rated voltage: 230 V~
Rated voltage tolerance: -15 ÷ +10 %
Rated frequency: 50 / 60 Hz
Rated current: 10 mA
Trigger terminals: IN(red)
Light intensity storage: - yes
Light control: single pole push button
Load supply indicator: red LED
Permissible load: 30 ÷ 300 W
Fuse technical specication: 5 x 20 mm, ultra-fast, 2 A / 250 V
Control: triac
Connection terminals quantity:
3
Connection wire section:
1 mm
2
Operating temperature:
-20 ÷ +45
o
C
Operating position:
optional
Casing fastening:
for 60 mm junction box
Casing IP:
IP40 (PN-EN 60529)
Protection class:
II
Overvoltage category:
II
Pollution level:
2
Dimensions:
50 x 50 x 15 mm
Weight:
28 g
Standard conformity:
PN-EN 60669-1; PN-EN 60669-2-1
PN-EN 61000-4-2,3,4,5,6,11
Load ON indicator
Load power lead
Power lead (L)
Fuse socket
Trigger lead (IN)
b
r
o
w
n
r
e
d
b
l
a
c
k
Load ON indicator
Load power lead
Power lead (L)
Fuse socket
Trigger lead (IN)
b
r
o
w
n
r
e
d
b
l
a
c
k
The device should be
connected to a single-
phase system accordin-
gly to current standards.
The device connection
swill be described in this
manual. Only qualied
electricians are allowed to connect,
assembly and adjust the timer. It is ne-
cessary to read this manual before the
timer mounting. Do not disassembly the
timer casing or you will lose any war-
ranty rights and expose yourself to the
electric shock hazard. Before mounting
operation make sure of disconnecting
the connection wires from the electric
network. Use a cross-head screwdriver
of 3.5 mm diameter to mount the devi-
ce. The timer should be carried, stored
and used in an appropriate way. Do not
mount the timer in case of any device
parts lack, damage or deformation. In
case of malfunction please notify the
manufacturer.