Installation Instructions
Safety instructions
Warning! This must be read!
The laws, ordinances, directives and
standards in force in the country of use
are to be followed (safety regulations,
proper recycling in accordance with the
regulations, etc.)
Installation may only be carried out by a
qualified electrician.
The minimum distances to other appli-
ances and units are to be observed.
Anti-shock protection must be provided
by the installation, for example drawers
may only be installed with a protective
floor directly underneath the appliance.
The cut surfaces of the worktop are to
be protected against moisture using a
suitable sealant.
The sealant seals the appliance to the
work top with no gap.
Do not use silicon sealant between the
appliance and the work top.
Avoid installing the appliance next to
doors and under windows. Otherwise
hot cookware may be knocked off the
rings when doors and windows are
opened.
z Risk of injury from electrical
current.
The electrical mains terminal is live.
Make electrical mains terminal free of
voltage.
Follow connection schematic.
Observe electrical safety rules.
Ensure anti-shock protection by in-
stalling correctly.
The appliance must be connected to
the electrical supply by a qualified
electrician.
z Risk of injury from electrical
current.
Loose and inappropriate plug and
socket connections can make the
terminal overheat.
Have the clamping connections cor-
rectly installed by a qualified electri-
cian.
Use strain relief clamp on cable.
In the event of single-phase or two-
phase connection, the appropriate
mains cable of type H05BB-F Tmax
90°C(or higher) or an equivalent type
must be used.
If this appliances mains cable is
damaged, it must be replaced by a
special cable (type H05BB-F Tmax
90°C; or higher) or an equivalent
type. The latter is available from the
Customer Care Department.
A device must be provided in the electri-
cal installation which allows the appli-
ance to be disconnected from the mains
at all poles with a contact opening width
of at least 3 mm.
Suitable isolation devices include line
protecting cut-outs, fuses (screw type
fuses are to be removed from the hold-
er), earth leakage trips and contactors.