User manual

Do not pull the mains cable to disconnect the appli-
ance. Always pull the mains plug.
The appliance must not be connected with an exten-
sion cable, an adapter or a multiple connection (risk
of fire). Check that the ground connection is in con-
formity with the standard and regulations force.
The power cable must be placed in such a way that
it does not touch any hot part.
Connect the appliance to the mains with a device
that lets to disconnect the appliance from the mains
at all poles with a contact opening width of minimum
3 mm, eg. automatic line protecting cut-out, earth
leakage trips or fuse.
None of a parts of the connection cable can not get a
temperature 90 °C. The blue neutral cable must be
connected to the terminal block label with "N". The
brown (or black) phase cable (fitted in the terminal
block contact marked with "L") must always be con-
nected to the live phase.
Replacement of the connection cable
To replace the connection cable use only H05V2V2-F
T90 or equivalent type. Make sure that the cable sec-
tion is applicable to the voltage and the working tem-
perature. The yellow/green earth wire must be approxi-
mately 2 cm longer than the brown (or black) phase
wire.
Building In
min. 55 mm
min. 650 mm
550 mm
30 mm
470 mm
min. 600 mm
B
A
A - supplied seal
B - supplied brackets
Caution! Install the appliance only on a worktop
with flat surface.
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be easy to re-
move and let an easy access in case a technical assis-
tance intervention is necessary.
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
a) Removable panel
b) Space for connections
Kitchen unit with oven
The hob recess dimensions must obey the indication
and the kitchen unit must be equipped with vents to let
a continuous supply of air. The electrical connection of
the hob and the oven must be installed separately for
safety reasons and to let easy remove oven from the
unit.
50 cm
2
360 cm
2
180 cm
2
120 cm
2
22