Operation Manual

30 electrolux
30
Instructions for the Installer
Installation and connection must be
done in compliance with the
regulations in force. Any
interventions must be carried out
when the appliance is switched off.
Only accredited engineers may work
on the appliance.
The manufacturer disclaims any
liability if the safety measures are not
observed.
Connecting to the electrical supply
Before connecting to the electrical supply, please
make sure:
- The fuse and the domestic electrical installation
must be designed for the max. load of the
appliance (see rating plate).
- The domestic electrical installation must be
equipped with a proper earth connection in
accordance with the regulations in force.
- The socket or the multi-pole off switch must be
easy to access after the appliance has been
installed.
The appliance is supplied without an electric
supply cable,therefore you will have to fit to it a
supply cable with standardplug, suitable to the
total electric load shown on the ratingplate.
The plug is to be inserted into a suitable wall
socket.
If you require a direct connection to the electric
network (mains), it will be necessary to fit
between the appliance and the mains an
omnipole switch, with a minimum gap between
contacts of 3 mm, suitable for the required load
and in compliance with rules in force. The
green & yellow ground wire must not be
interrupted by the switch, and should be 2-3
cm longer than the phase and neutral wires.
The supply cable must in all cases be laid out
in such a way as to ensure that it does not
reach at any given point a temperature 50°C
higher than the ambient temperature.
Suitable power supply cables are the following
types, considering the respective necessary
section of cable: H07 RN-F, H05 RN-F, H05
RR-F, H05 VV-F, H05 V2V2-F (T90), H05
BB-F.
Terminal block
The oven is fitted with an easily accessible terminal
block which is designed to operate with a single-
phase power supply of 230 V.
Letter L - Live terminal
Letter N- Neutral terminal
or E - Earth terminal