DFZ MANUALE USO E MANUTENZIONE USE AND MAINTENANCE INSTRUCTIONS INSTRUCTIONS D'UTILISATION ET D'ENTRETIEN BEDIENUNGS- UND WARTUNGSANLEITUNG MANUAL DE USO Y MANTENIMIENTO
To carry out the instructions more easily, open the cover flap containing the key for the various functions
ENGLISH GB
TABLE OF CONTENTS pag. Preliminary information 48 Important safety warnings 48 Warranty 50 How to order spare parts 51 Disposing of the packing 51 Disposing of the machine 51 1. Description of the machine 52 1.1 Available models 52 1.2 Main technical specifications 52 2. Rating plate 57 3. Description of the central control unit 58 3.1 Description of the display (keys) 4. Operation 58 59 4.1 Before operating the unit 59 4.2 Setting the unit at work 59 4.
4.8 Time and display contrast programming 65 4.8.1 Continuous operation 66 4.8.2 Disabling Diesel operation 66 4.8.3 Keyboard block 67 4.8.4 Print or record data 68 4.9 70 Alarms 5. Goods loading procedure GB 74 5.1 Storage and stacking 74 5.2 Mobile partitions 75 5.3 Tips on the temperatures of carried goods 75 5.4 Recommendations on how to best use 75 your refrigerator unit 6. Using the unit safely 76 6.1 Engine coolant 76 6.2 Refrigerants 76 6.3 Battery 76 7.
Preliminary information Thank you for choosing one of the models of DFZ ZANOTTI refrigeration units. This manual is addressed to the operators of DFZ ZANOTTI refrigeration units. Inside you will find the necessary information to use and service the products correctly, safety tips, warranty terms as well as suggestions on the best way of transporting your goods. If you follow such instructions, you will be able to minimize the service operations required and to extend the life of your unit.
Safety Tips By drilling the walls of the unit or the isothermal cold room, you could damage the electric wires or the refrigeration piping. Should such action be strictly necessary, great care should be taken to avoid any damage. Touching turning fans and moving belts can cause irreparable damage or injury. Be careful with the blades of the condenser and evaporator; their edges are very sharp.
Engine The PERKINS engines fitted on all DFZ ZANOTTI refrigeration units are designed to keep pollution caused by exhaust gas at a minimum level. However, we strongly recommend to avoid starting the engine in a confined area, as the exhaust gas is toxic. The symptoms caused by carbon monoxide produced by fuel combustion are the following: – dizziness – strong headache – sleepiness – vomiting. If you should experience these symptoms with the engine on, try to breath clean air immediately.
How to order spare parts When ordering spare parts, always include the serial number shown on the machine's rating plate. Disposing of the packing Dispose of all wooden, plastic and polystyrene packing in compliance with the laws in force in the Country where the equipment is used. GB Disposing of the machine Should the machine be scrapped, its components must not be scattered in the environment.
1. Description of the machine The DFZ refrigeration units are made up of the following main components: 1. a condensing unit installed outside the isothermal box; 2. an evaporating unit installed inside the isothermal box; 3. an electronic central control unit located in the driver's cab of the vehicle. All models are suitable to store products both at positive and negative temperatures. 1.
DFZ 430 P. on road P. rmains Refrigeration power Amb. t. 30°C Cold room t. 0°C 6098W 4951W Amb. t. 30°C Cold room t. -20°C 3724W 3014W cm3 Road/mains compressor 170 Road engine Perkins 676 cm3 Condenser fan No. 1 helical-type belt-driven fan Air flow rate 2100 m3/h Evaporator fan N° 2 helical-type direct-drive fans Air flow rate 2200 m3/h Electric motor for mains op. power supply 400/3 /50 Hz – 3000W Refrigerant R404A GB DFZ 435 P. on road P. rmains Refrigeration power Amb. t.
DFZ 465 P. on road P. rmains Refrigeration power Amb. t. 30°C Cold room t. 0°C 9500W 7848W Amb. t. 30°C Cold room t. -20°C 5400W 3555W cm3 Road/mains compressor 230 Road engine Perkins 954 cm3 Condenser fan No. 1 helical-type belt-driven fan Air flow rate 3500 m3/h Evaporator fan N° 3 helical-type direct-drive fans Air flow rate 3600 m3/h Electric motor for mains op. power supply 400/3 /50 Hz – 5.500W Refrigerant R404A DFZ 495 P. on road P. rmains Refrigeration power Amb. t.
DFZ 465U (Cubic Evaporator) P. on road P. rmains Refrigeration power Amb. t. 30°C Cold room t. 0°C 10908W 6090W Amb. t. 30°C Cold room t. -20°C 6636W 3868W cm3 Road/mains compressor 235 Road engine Perkins 957 cm3 Condenser fan No. 1 helical-type belt-driven fan Air flow rate 3500 m3/h Evaporator fan N° 3 helical-type direct-drive fans Air flow rate 3600 m3/h Electric motor for mains op. power supply 400/3 /50 Hz – 5,5KW Refrigerant R404A GB DFZ 495U (Cubic Evaporator) P. on road P.
DFZ 465U (Flat Evaporator) P. on road P. rmains Refrigeration power Amb. t. 30°C Cold room t. 0°C 9739W 5561W Amb. t. 30°C Cold room t. -20°C 5630W 3098W cm3 Road/mains compressor 235 Road engine Perkins 954 cm3 Condenser fan No. 1 helical-type belt-driven fan Air flow rate 3500 m3/h Evaporator fan N° 3 helical-type direct-drive fans Air flow rate 5875 m3/h Electric motor for mains op. power supply 400/3 /50 Hz – 5,5KW Refrigerant R404A DFZ 495U (Flat Evaporator) P. on road P.
2. Rating plate The DFZ ZANOTTI units are identified by plates located on the right side of the condensing circuit. They contain all the information to be communicated to the technicians in case of servicing, i.e.: – model – serial number – voltage – electrical input – refrigerant – weight of the unit GB 11) Year of manufacture 12) ZANOTTI unit code 13) Serial number 14) Voltage: Road (V d.c.
3. Description of the central control unit The DFZ ZANOTTI refrigeration units are equipped with a microprocessor-based electronic controller (driver's cabin control) which manages operation in a fully automatic way. In particular, the electronic controller supervises the operations for turning the diesel engine and electric motor on and off depending on the set temperature. Operation selection (diesel or electric) is automatically carried out by connecting the provided plug to the mains. fig. 1 3.
4. Operation 4.1 Before operating the unit 1. Check the belts. In fact, their tension must be perfect in order to prevent them from slipping if they are too slack (as this would generate heat and would therefore shorten the life of the belts) or the bearings from wearing out too fast if the belts are too tight. It is a very easy check: pressing slightly at the center of the longest side of the belt, there should be a slack of 8 to 12 mm (5/16 in. to 15/32 in.
4.2 Setting the unit at work Press push-button 1 to turn on the driver's cabin control. The mask shown in fig. 2 will appear after a few seconds. This mask shows: • TA1: Cold room temperature • SP1: operating set point • current date and time, • type of diesel operation, either slow (LOW) or fast (HIGH). fig. 2 CAUTION Only use push-button 1 to turn off (or on) the electronic control unit if the refrigeration unit is not used. Always use the button only to turn the refrigerator on and off (fig. 2). 4.
If two cold rooms are present, the mask will appear: To program the set point of the second cold room SP2, proceed as follows: - Press key : the cursor will start blinking under the present SP1 set point value. - Press the key until the value relating to SP2 is highlighted. GB - Press the UP/DOWN key to change such value. - Press key to store the defined value. 4.4 Turning on the refrigeration unit Press the button of the driver's cabin control to turn on the refrigeration unit.
WARNING If the plug is connected before the diesel engine is stopped using the button (fig. 2), the diesel engine will turn off and the electric motor will come on after approximately 5 minutes. Similarly, if power is interrupted during electric standby, automatic startup of the diesel engine will take place after 5 minutes. 4.5 Defrost Defrost is fully automatic. If needed, a defrost cycle can be forced by pressing key .
In this mask, you can see for how many hours the oil and oil filter have been used, as well as the total working hours of the diesel engine and electric motor. When the oil or oil filter have been used for over a limit number of hours, the symbol will be displayed on the main mask; then, accessing the maintenance mask the icons or will be displayed, to show that either the oil needs changing or the oil filter element needs replacing.
USER'S HANDBOOK UPDATE The cabin command has a slightly different graphic display and several new functions. The main window is as shown in the figure below: In this window three indications can be seen at the top left: which indicates the automatic function (start/stop); the snow-flake which indicates turning on of cold; which indicates the slow Diesel operational mode.
4.8 Time and display contrast programming Starting from the main mask and pressing key first and then key , you will access the mask below. By pressing key you can access the clock programming mask: GB press key to highlight the day, press the key to go from one term to another, press the UP/DOWN key to set the new value. Confirm the new value by pressing key By pressing key .
4.8.1 Continuous operation This function allows the start/stop function of the Diesel motor to be cut-out and kept in motion in a continuous way; to activate this function starting from the main window press the key then press the key , instead of , the following window appears: , will appear on the display indicating activation of the continuous function. 4.8.
4.8.3 Keyboard block To prevent unwanted interventions the keyboard blocking function has been introduced; activate it starting from the main window, press the key then the key and , in this way the following window is accessed: GB now press the key , to go to the following window where entering the password will automatically bring up the following window which will be the only one that can be displayed and the on/off key will be the only active key.
To unblock the keyboard press the MENU key and re-enter the password in the following window 4.8.4 Print or record data In the following window, reached by pressing and the key from the main window is the key which when pressed accesses the window where the following con be entered: From: the data printing start date To: the end of printing date Evp: which temperature to be printed (evaporator 1, 2 or 3) Res: with what resolution (every 10 min, 20, 30 etc.) Sta: start of printing time Sto.
Example: From: 10/04/01 To: 12/04/01 Evp: 1 Res: 10 min Sta: 12:00 (noon) Sto. 14:00 (2 p.m.) Prn: PRINTER With the data thus entered press the key to print all the data from 10/04/01 GB to 12/04/01 recorded from 12 noon to 2 p.m. every 10 minutes. Whenever using download on PC, the Hyperterminal present in the windows accessories must be accessed.
4.9 Alarms Every time an alarm occurs, the icon starts blinking and the buzzer goes off. To silence the buzzer, just press any key. To see the alarm mask, press key ; in this way, you will access the mask below where you will see the different alarm codes. Each alarm code has a relevant description which can be seen in the string at the bottom of the display. ON indicates an active alarm status while OFF indicates a non-active one.
Alarm code Description Type A01 Water temperature alarm Automatic reset A02 Oil pressure alarm Manual reset A03 Thermal relay alarm Manual reset A04 Pressure switch alarm Automatic reset A05 Low battery level alarm Automatic reset A06 Damaged room sensor alarm Manual reset A07 Damaged defrost sensor alarm Warning only A08 Starting failure/damaged alternator Manual reset A09 High/low temperature alarm Warning only A10 Radiator water level alarm Warning only A11 Oil level ala
A04 Pressure switch alarm This alarm occurs when either the high or low pressure switch trips. The high pressure switch may trip due to poor cleaning of the condenser or loosened condenser fan belts. The low pressure switch may trip due to refrigerant leaks. By tripping it causes the machine to stop until the alarm itself disappears. A05 Low battery level alarm This alarm occurs if battery power is lower than 11.5V. It turns the machine off until power remains above 11.5V for at least 1'.
A11 Oil level alarm (optional) It is a warning alarm which has no consequences on the operation of the machine. A12 Air filter alarm This alarm occurs if the air filter cartridge is clogged. Replace the cartridge. It is a warning alarm which has no consequences on the operation of the machine. A13 Oil filter alarm (optional) It is a warning alarm which has no consequences on the operation of the machine.
5. Goods loading procedure 5.1 Storage and stacking One of the main concerns to take into account when storing goods, is how to ensure proper air circulation in the isothermal cold room. If the air cannot circulate freely throughout the cargo, ice or warm areas will almost certainly develop, which could irreparably damage the goods. One of the first tips to avoid this, is to store the goods on pallets.
5.3 Tips on temperature of carried goods Product -Reference temperature Bananas -15°C (55/60°F) Fresh fruit and vegetables -4/6°C (39/43°F) Fresh meati and seafood -2°C (36°F) Milk and dairy products -2/6°C (36/43°F) Ice-cream -20/-25°C (-15/-20°F) Deep frozen fruit and vegetables -18°C (0°F) Deep frozen meat and fish -20°C (-10/0°F) THESE TEMPERATURES ARE FOR REFERENCE PURPOSES ONLY. ANY TEMPERATURE SUPPLIED BY RECEIVER OR CARRIER WILL PREVAIL. GB 5.
6. Using the unit safely The DFZ ZANOTTI units are built to keep the operators safe. The use of protection gloves is, in any case, fundamentally important during controls, repairs, and maintenance for every action which the operator must carry out inside the unit, whether when handling the evaporator or the condenser which can injure his hands with their fins or to avoid burns caused by accidental contact with the unit's hot parts. 6.
7.
Important • Carry out the following maintenance operations after one year: - renovating refrigerant, - checking and adjusting valve clearances, - checking that the cylinder heads are well tightened, - checking that the injectors are in good working condition. BELTS Properly tensioned belts allow a good transmission and wear out less. Caution: should one of the pairmounted belts need servicing, it is ABSOLUTELY necessary replace both belts. FILTERS 1. Oil filter 2. Diesel fuel filter 3.
8. Troubleshooting guide Trouble Checks to carry out On turning on, the engine does not start • Flat battery. • Battery connections. • Fuses. The unit won't start • Fuel level. • Engine oil level. • Fuses. The unit jams • • • • • The unit does not cool properly Belts tension. Engine oil level. Coolant level. Fuel level. Fuses. GB • Defrost the unit. • Something hinders the proper ventilation of the evaporator. • Something hinders the proper ventilation of the condenser.
9. Abstract of the “A.T.P. Europe” regulation (march 1974) Authorization for vehicles used to carry perishable foodstuffs. Prior to the beginning of its operation, the refrigerated vehicle must be authorized by the Departmental Veterinary Service. CHARACTERISTICS OF VEHICLES USED TO CARRY PERISHABLE FOODSTUFFS REFRIGERATED VEHICLE.
SYMBOLS, ITEMS AND IDENTIFICATION PLATES TO BE AFFIXED ON REFRIGERATED VEHICLES.
Wiring diagram key ALT Alternator KFP Diesel fuel pump relay BA Room sensor KPO Oil pressure switch relay BH Radiator sensor KPR-1-2 Crankcase heating relay E1 Glow plugs KRF Timer for cooling fan delay ES Heaters on condensate KSF Phase sequencer drain pipes KYAV High speed solenoid valve relay FM1 Automatic switch KYS Defrost solenoid valve relay F1E Electronic control unit KS1 Central control unit F8-9-10 Evaporators fans fuses F1 Fuse for auxiliary evaporator M1 Elect
Tagliando di garanzia Guarantee coupon - Coupon de garantie - Garantieabschnitt - Cupón de garantía 50 ORE O 15 GIORNI DALLA MESSA IN SERVIZIO 50 hours or 15 days from start-up date - 50 heures ou 15 jours à partir de la mise en service Stunden oder 15 Tage ab Inbetriebsetzung - 50 horas o 15 días a partir de la puesta en marcha Data Timbro officina autorizzata ZANOTTI Date - Date - Datum - Fecha Seal of the ZANOTTI authorized repair shop - Tampon du centre agréé ZANOTTI Stempel der autorisierten ZANOT
Tagliando di garanzia Guarantee coupon - Coupon de garantie - Garantieabschnitt - Cupón de garantía 1000 ORE O 10 MESI DALL’ULTIMO TAGLIANDO 1000 hours or 10 months from the last service - 1000 heures ou 10 mois à partir du dernier coupon de révision 1000 Stunden oder 10 Monate ab der letzten Wartung - 1000 horas o 10 meses a partir de la última revisión Data Timbro officina autorizzata ZANOTTI Date - Date - Datum - Fecha Seal of the ZANOTTI authorized repair shop - Tampon du centre agréé ZANOTTI Stemp