User manual

7
Synthetic Grease Filter
The grease filter has saturation indicators,
which are small squares made from a series of
dots. When the white paper inside the squares
becomes saturated with grease the coloured
dots start to run and spread across the paper,
indicating that the filter has reached saturation
point and must be replaced.
The synthetic grease filter
cannot be cleaned.
It must not be washed.
K
To Replace the Synthetic
Grease Filter
1. Remove the lower grille.
2. Push the wire retaining clips to the
side and remove.
3. Clean the metal grille and clips before
replacing the paper grease filter.
The clips have sharp points, handle with
care and keep away from children.
This appliance is a possible fire
hazard if the grease and charcoal
filters are not replaced as
recommended.
Changing the Light Bulb
The bulb should be replaced with a 220-240
volt 40 watt clear cylindrical shape bulb with a
small Edison (E14) screw thread.
Replacement filters, and light bulbs can be
obtained from your local Service Force Centre.