Handy Dri 24 Fitting Instructions and User Guide
Please read and understand these instructions prior to installing your Handy Dri hand drier. They are for use by competent personnel i.e. trained, experienced and qualified. Instructions only detail key operations. They do not supersede national, mandatory or legal requirements which may apply to the product, installation, environment or personnel associated with servicing the Handy Dri. Particular attention should be paid to the section headed IMPORTANT INSTALLATION POINTS.
1.0 SAFETY INSTRUCTIONS 1.1 1.2 Always disconnect from the mains before removing the cover. Do not run the Handy Dri with the cover removed or the motor will not be effectively cooled. Please note that improper use of electrical appliances can give rise to hazards that children can not recognise. 2.0 IMPORTANT INSTALLATION POINTS 2.1 2.2 2.3 2.4 2.5 Check the mains electrical supply is within the range 230V to 240V 50/60Hz before connecting the Handy Dri.
3.0 INSTALLATION WALL MOUNTING 3.1 3.2 3.3 3.4 3.5 To remove the cover: Completely unscrew the two screws located on the underside of the unit, using the special hexagon wrench supplied. Lift the cover away from the backplate, and over the sensor housing, before removing the cover completely. Choose the mounting position for the Handy Dri taking into account : • The position of the electrical connection. • The recommended height, (see the mounting template).
4.0 INSTALLATION ELECTRICAL REQUIREMENTS WARNING: This appliance must be earthed. It is suitable for a.c. supply only. Disconnect the electrical supply before removing the cover. Installation must be in accordance with the current local Wiring Regulations. 4.1 A double pole isolating switch, with a contact separation of at least 3mm in both poles, should be incorporated in the electrical supply. The supply should be fused 13 Amp. 4.2 The nominal cross sectional area of the supply cable should be 1.
Figure 1: Wiring Diagram Sensor 7 Schematic Circuit Diagram 6 5 M 4 Timer Motor Heater 2 Relay Contact 3 1 Thermostat L N
5.0 OPERATION 5.1 5.2 5.3 The Handy Dri is fitted with an infrared system which detects the presence of the hands. To turn the unit on place the hands 10 to 30 cm below the air nozzle and the unit will automatically start. When the hands are withdrawn the unit will automatically stop. 6.0 MAINTENANCE 6.1 6.2 To keep the Handy Dri operating efficiently and to prolong the life, the inlet grill and outlet nozzle should be regularly vacuumed.
.0 FAULT FINDING SAFETY NOTE: DISCONNECT THE ELECTRICAL SUPPLY BEFORE REMOVING THE COVER. DO NOT BYPASS ANY SAFETY CONTROLS SYMPTOM Unit does not turn on. POSSIBLE CAUSE ACTION 1. Local switch off. 2. Local fuse blown. 3. Circuit breaker at main board off. 4. Sensor not fully located in the front cover. 5. Sensor wire disconnected. 6. Motor fuse and thermal fuse blown. 7. Thermostat faulty. 1. Turn local switch on. 2. Replace local fuse. 3. Re-set breaker. Motor runs intermittently. 1. Brushes worn.
.0 GUARANTEE The Handy Dri 24 is guaranteed for a period of five years from the date of purchase provided: 1. The unit has been installed in accordance with these instructions. 2. The unit has not been tampered with and has been regularly maintained as detailed in the maintenance instructions. The guarantee excludes normal motor brush wear and tear. This guarantee does not affect the statutory rights of the consumer. 10.
NOTES
Spares Stockists For the fast and efficient supply of spares please contact the stockists listed below. Parts Center PO Box 48, Tomlinson Road, Leyland, Preston, Lancashire, PR5 1JX Tel: 01772 819671 www.partscenter.co.uk Electric Water Heating Co 2 Horsecroft Place, Pinnacles, Harlow, CM19 5BT Tel 0845 0553811 Email : sales@ewh.co.