SECURING THE APPLIANCE TO THE
CABINET
A
B
ELECTRICAL INSTALLATION
The manufacturer is not responsible if
you do not follow the safety
precautions from the Safety chapters.
This appliance is supplied with a main plug and a
main cable.
CABLE
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05
V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total power
on the rating plate. You can also refer to the table:
Total power (W)
Section of the cable
(mm²)
maximum 1380 3 x 0.75
maximum 2300 3 x 1
maximum 3680 3 x 1.5
The earth cord (green / yellow cable) must be 2 cm
longer than phase and neutral cables (blue and
brown cables).
TECHNICAL DATA
TECHNICAL DATA
Voltage 220 - 240 V
Frequency 50 / 60 Hz