Operation Manual

Kitchen unit with oven
The electrical connection of the hob and the oven
must be installed separately for safety reasons and
to let easy remove oven from the unit.
TECHNICAL DATA
HOB DIMENSIONS
Width 594 mm
Depth 510 mm
BYPASS DIAMETERS
BURNER Ø BYPASS 1/100 mm
Rapid 42
Semi-rapid 32
Auxiliary 28
OTHER TECHNICAL DATA
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 8 kW
Gas replacement: G30 (3+) 28-30 mbar = 567 g/h
G31 (3+) 37 mbar = 557 g/h
Electric supply: 220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp car-
tridge fuse
Appliance category: II2H3+
Gas connection: R 1/2"
Appliance class: 3
GAS BURNERS FOR NATURAL GAS G20 20 MBAR
BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK
Rapid 3,0 0,75 119
Semi-rapid 2,0 0,45 96
Auxiliary 1,0 0,33 70