User manual
Cleaning of the spark plug
This feature is obtained through a ceramic igni-
tion candle with a metal electrode. Keep these
components well clean to prevent difficult light-
ing and check that the burner crown holes are
not obstructed.
Periodic maintenance
Periodically speak your local Service Force
Centre to check the conditions of the gas sup-
ply pipe and the pressure adjuster, if fitted.
What to do if…
Problem Possible cause Remedy
There is no spark when lighting
the gas
• There is no electrical supply • Make sure that the unit is con-
nected and the electrical supply
is switched on.
• Control the fuse. If the fuse is
released more than one time,
refer to a qualified electrician.
• Burner cap and crown are
placed uneven
• Make sure that the burner cap
and crown are in correct posi-
tions.
The flame is blow out immediately
after ignition
• Thermocouple is not heated
sufficient
• After lightning the flame, keep
the knob pushed for approxi-
mately 5 seconds.
The gas ring burns unevenly • Burner crown is blocked with
food residues
• Make sure that the injector is
not blocked and the burner
crown is clear of food particles.
23