Operation Manual

min 30 mm
60 mm
min 5 mm
(max 150 mm)
A
B
A. Removable panel
B. Space for connections
Kitchen unit with oven
The electrical connection of the hob and the oven
must be installed separately for safety reasons and
to let easy remove oven from the unit.
TECHNICAL DATA
HOB DIMENSIONS
Width 744 mm
Depth 510 mm
BYPASS DIAMETERS
BURNER Ø BYPASS 1/100 mm
Multi Crown 57
Rapid 42
Semi-rapid 32
Auxiliary 28
OTHER TECHNICAL DATA
TOTAL POW-
ER:
Gas original: G20 (2H) 20 mbar 12,0 kW
Gas replace-
ment:
G30 (3+) 28-30 mbar 832 g/h
G31 (3+) 37 mbar 818 g/h
Electric supply: 220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse
Appliance cate-
gory:
II2H3+
Gas connec-
tion:
R 1/2"
Appliance
class:
3
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK
Multi Crown 4,0 1,4 146
15