Operation Manual

BURNER Ø BYPASS 1/100 mm
Semi-rapid 32
Auxiliary 28
OTHER TECHNICAL DATA
TOTAL POWER:
Gas original: G20 (2H) 20 mbar 11,0 kW
Gas replace-
ment:
G30 (3+) 28-30 mbar 800 g/h
G31 (3+) 37 mbar 786 g/h
Electric supply: 220-240 V ~ 50/60 Hz
Appliance cate-
gory:
II2H3+
Gas connection: G 1/2"
Appliance class: 3
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK
Triple Crown 4,0 1,4 146
Semi-rapid 2,0 0,45 96
Auxiliary 1,0 0,33 70
GAS BURNERS FOR LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30 mbar G31 37 mbar
Triple
Crown
4,0 1,4 98 291 286
Semi-rapid 2,0 0,45 71 145 143
Auxiliary 1,0 0,33 50 73 71
ENERGY EFFICIENCY
PRODUCT INFORMATION ACCORDING TO EU 66/2014
Model identification ZGH78534XA
Type of hob Built-in hob
14