INSTRUCTION BOOKLET COOKER HOOD ZHC605 ZHC705 ZHC905
Thank you for buying a Zanussi product. To enable you to use your appliance effectively and safely, please read this instruction book carefully before using the appliance and retain for future reference. If you require guidance in the use of the appliance or require further information on Zanussi Products, please contact our Customer Care Department. For general enquiries concerning your Zanussi appliance or for further information, visit our website at http://www.zanussi.co.
IMPORTANT SAFETY INFORMATION These warnings are provided in the interests of your safety. Ensure that you understand them all before installing or using this appliance. Your safety is of paramount importance. If you are unsure about any of the meanings of these warnings contact the Customer Care Department. Installation • Any installation work must be undertaken by a qualified electrician or a competent person. Child Safety • This appliance is designed to be operated by adults.
YOUR APPLIANCE 598- 698 - 898 OPERATING INSTRUCTIONS The cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam. The appliance can be installed to recirculate or extract contaminated air. Cooker Hood Controls The cooker hood functions are controlled by three switches located on the underside of the hood immediately in front of the metal grease filters. Worktop Lighting The switch (L) marked with the lamp symbol operates the worktop lighting.
To Operate Select the required fan speed and light if required. Recirculation In the recirculation mode the contaminated air enters the cooker hood through the grease filters. The air is cleaned by passing through the charcoal filters before being passed back into the kitchen through the grilles in either side of the chimney stack. Extraction In the extraction mode the contaminated air enters the cooker hood passing through the grease filters and is passed out through the ducting into the atmosphere.
MAINTENANCE AND CLEANING Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply. The cooker hood must be kept clean, as a build up of grease or fat can be a fire hazard. External Cleaning Wipe the cooker hood frequently with warm soapy water using a mild detergent. Never use scouring pads or abrasive cleaners. Never use excessive amounts of water when cleaning particularly around the control panel.
MAINTENANCE AND CLEANING Charcoal Filters In the recirculation mode the charcoal filters absorb smells and unwanted odours. The charcoal filters cannot be cleaned, we recommend they should be replaced approximately every three months or more often if the hood is used for more than three hours per day. To Remove/Replace the Charcoal Filters 1. First remove the metal grease filters. 2. Rotate the charcoal filter anti-clockwise (A) and remove. 3.
SOMETHING NOT WORKING If, having followed these instructions carefully, your cooker hood fails to work properly please carry out the following checks. Symptom Solution The cooker hood will not start • Check the hood is connected to the electricity supply. • Make sure the switch is in the ‘ON’ position. The cooker hood is not working effectively • The fan speed is set high enough for the task • The grease filter is clean. • The kitchen is adequately vented to allow the entry of fresh air.
GUARANTEE CONDITIONS We Zanussi, undertake that if within twenty four months of the date of the purchase this Zanussi built-in appliance or any part thereof is proved to be defective by reason only of faulty workmanship or materials, the company will, at our option repair or replace the same FREE OF ANY CHARGE for labour, materials or carriage on condition that: • • • • • The appliance has been correctly installed and used only on the electrical supply stated on the rating plate.
INSTALLATION INSTRUCTIONS It is dangerous to alter the specifications or attempt to modify this product in any way.
INSTALLING THE COOKER HOOD Please ensure that when the appliance is installed it is easily accessible to an engineer in the event of a breakdown. All installations must comply with the local authorities requirements for the discharge of exhaust air. Incorrect installation may affect the safety of this cooker hood. Installation Requirements Before installation check the wall to which the cooker hood is to be fitted for electric cables, water pipes or gas.
INSTALLING THE COOKER HOOD Clearance Height The cooker hood is designed to be fitted over a cooking appliance at the clearance heights stated, providing the maximum output of the appliance beneath does not exceed the maximums quoted in the Technical Specifications. If the output of the appliance below the cooker hood exceeds the maximum outputs quoted, please refer to the cooker manufacturer’s installation instructions.
INSTALLING THE COOKER HOOD • • • • Drill ø 8 mm holes at all the centre points marked. Insert the wall plugs (not supplied) in the holes. Fix the brackets using the screws (not supplied). Fix the back panel (where present) using the screws (not supplied). Note: If the hood is to be installed onto a hollow construction or plaster or partition board wall then special fixing screws will be required (not supplied). 1÷2 Fitting the Wall Brackets 95 95 210 7.1 X 7.2.1 H 650 min.
INSTALLING THE COOKER HOOD Extraction (Ducted) The cooker hood is more effective when installed in the extraction mode (ducted to the outside). Venting kits may be purchased through your retailer or DIY store or using the enclosed form, and must be evacuated through an outside vent of ø125 (5ins) or ø150mm (6ins). The ducting used must be manufactured from fire retardent material conforming to the relevant British Standard or DIN 4102-B1.
INSTALLING THE COOKER HOOD Fitting the Upper Chimney 12c • Slightly widen the two sides of the upper chimney and hook them behind the brackets item 7.2.1 ensuring they are correctly seated. • Secure the sides to the brackets using the 4 screws item 12c (2.9 x 9.5mm) supplied. 2.2 2 12c 2.1 Fitting the Lower Chimney • Slightly widen the two sides of the lower chimney and hook them between the upper chimney and the wall, ensuring they are correctly seated.