Securing the appliance to the cabinet
A
B
Electrical installation
The manufacturer is not responsible
if you do not follow the safety
precautions from the Safety
chapters.
This appliance is supplied only with a main
cable.
Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F,
H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total
power on the rating plate. You can also refer to
the table:
Total power (W) Section of the ca-
ble (mm²)
maximum 1380 3 x 0.75
maximum 2300 3 x 1
maximum 3680 3 x 1.5
The earth cord (green / yellow cable) must be 2
cm longer than phase and neutral cables (blue
and brown cables).
Energy efficiency
Product Fiche and information according to EU 65-66/2014
Supplier's name Zanussi
Model identification ZOB21601XK
Energy Efficiency Index 105.9
Energy efficiency class A