User manual

Problem Possible cause Solution
The appliance has no power. There is
no voltage in the mains socket.
Connect a different electrical appliance
to the mains socket. Contact a qualified
electrician.
The lamp does not work. The lamp is in stand-by. Close and open the door.
The lamp is defective. Refer to "Replacing the lamp".
If your appliance is still not working properly after making
the above checks, contact the After Sales Centre.
Replacing the lamp
1. Disconnect the appliance.
2. Push the movable part to unhook the lamp cover (1).
3. Remove the lamp cover (2).
4. Replace the lamp with one of the same power and
specifically designed for domestic appliances only.
5. Install the lamp cover.
6. Connect the appliance.
7. Open the door. Make sure that the lamp comes on.
1
2
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "Installation".
3. If necessary, replace the defective door gaskets.
Contact the Service Center.
Technical data
ZRB934XL
ZRB934PW
ZRB936XL ZRB936PW ZRB940XL
ZRB940PW
Dimension
Height 1750 mm 1850 mm 2010 mm
Width 595 mm 595 mm 595 mm
Depth 658 mm 658 mm 658 mm
Rising Time 20 h 20 h 20 h
Voltage 230 V 230 V 230 V
Frequency 50 Hz 50 Hz 50 Hz
The technical information are situated in the rating plate
on the internal left side of the appliance and in the energy
label.
Installation
Caution! Read the "Safety Information" carefully for
your safety and correct operation of the appliance
before installing the appliance.
Positioning
Install this appliance at a location where the ambient tem-
perature corresponds to the climate class indicated on the
rating plate of the appliance:
21