SDS

Table Of Contents
Occupational exposure limit values (Workplace Exposure Limits)
Coun-
try
Name of agent CAS No Identi-
fier
TWA
[ppm]
TWA
[mg/m³]
STEL
[ppm]
STEL
[mg/m³]
Ceiling-C
[ppm]
Ceiling-C
[mg/m³]
Nota-
tion
Source
US petroleum distil-
lates (naphtha)
(rubber solvent)
64742-48-9 PEL 500 2,000 29 CFR
1910.10
00
US mineral oil 8042-47-5 TLV® 5 i, ex-
Met-
WorkFl
ACGIH®
2023
Notation
+asb containing asbestos fibers
appx-A NIOSH Potential Occupational Carcinogen (Appendix A)
appx-C Appendix C - Supplementary Exposure Limits
CA-10 Respirable fibers: length > 5µm; aspect ratio ≥ 3:1, as determined by the membrane filter method at 400-450 times mag-
nification (4-mm objective), using phase-contrast illumination.
Ceiling-C ceiling value is a limit value above which exposure should not occur
dust as dust
exMetWork-
Fl
excluding metal working fluids
fib/cm³ fibers/cm³
fib/ml fibers/ml
fine fineparticle
i inhalable fraction
less1silica with less than 1 % free crystalline silica
lowest exposure by all routes should be carefully controlled to levels as low as possible
nano nanoparticle
no_asb containing no asbestos fibers
noAsb_less1
Sil
contains no asbestos and less than 1% free crystalline silica
PAHs as polycyclic aromatic hydrocarbons (PAHs)
partml particles/ml
r respirable fraction
STEL short-term exposure limit: a limit value above which exposure should not occur and which is related to a 15-minute peri-
od (unless otherwise specified)
TWA time-weighted average (long-term exposure limit): measured or calculated in relation to a reference period of 8 hours
time-weighted average (unless otherwise specified
8.2 Exposure controls
Appropriate engineering controls
General ventilation.
Individual protection measures (personal protective equipment)
Eye/face protection
Wear eye/face protection.
Skin protection
- Hand protection
Wear suitable gloves. Chemical protection gloves are suitable, which are tested according to EN 374. Check leak-
tightness/impermeability prior to use. In the case of wanting to use the gloves again, clean them before taking off
and air them well. For special purposes, it is recommended to check the resistance to chemicals of the protective
gloves mentioned above together with the supplier of these gloves.
- Other protection measures
Take recovery periods for skin regeneration. Preventive skin protection (barrier creams/ointments) is recommended.
Wash hands thoroughly after handling.
Respiratory protection
In case of inadequate ventilation wear respiratory protection.
Environmental exposure controls
Use appropriate container to avoid environmental contamination. Keep away from drains, surface and ground water.
Safety Data Sheet
acc. to 29 CFR 1910.1200 App D
ZAR® SB Semi-Transparent Deck and Siding - Barnboard
Version number: REV 6.0
Replaces version of: 2023-02-22 (REV 5)
Revision: 2023-05-01
United States: en
Page: 7 / 19