Owner`s manual

6
ADDENDUM 2:
June 23 2004
Some software features have changed, or are in the process of changing, since this
manual was written. This Addendum discusses those changes. They are in no
particular order.
REFERENCE TONE (12.7) The Reference Tone is 1kHz at 48k Sampling Rate. The
tone frequency is purposely tied to the Sampling Rate to provide a quick reference to
confirm the rate. At 44.1K the tone is 918 Hz, at 96K it’s 2 kHz, and at 192K it’s 4 kHz.
EXTERNAL AES (12.2.1) The External AES setting takes it’s reference from an
external source such as a digital mixer. Both the external source AND the DEVA must
be set for the same sampling rate or else the time code will drift. Also, the External AES
setting takes it’s sync from AES inputs 1 and 2, so when in EXTERNAL AES mode you
MUST use those inputs. You cannot run external AES solely to any other pairs of
inputs. Also, the EXTERNAL AES will revert to internal sync if the external signal is lost.
In a later software revision the home screen will indicate the loss of external sync. It is
recommended that you leave this setting in AUTO. The Deva can only function as an
AES slave. It can lock to external AES inputs. It can not run on internal reference and
input aes at the same time. If external AES is used the Deva must be on external
reference.
CURRENT DRAIN The Deva draws approximately 750ma under full load. This load will
drop in a future software revision. As of now, all the A to D converters are ON all the
time. In the later revision, unused converters will turn themselves off decreasing power
draw.
CUE MENU (18.3) To playback anytake you must currently use the CUE MENU and
press ENT SEG #, then use the number pad to enter the actual number, then hit ENT
SEG # again and then hit the PLAY button. In a later software revision you will be able
to use the front panel and just punch in the segment # on the keypad, hit the CUE button
and PLAY.
BATTERY DISPLAY The On-Screen battery display currently shows the voltage of the
internal battery. In a later software revision it will show the voltage of whichever source
(internal or external) that is powering the DEVA.
NAME SELECTED FOLDER (14.2.3) Now allows you to enter up to 10 alpha-numeric
characters.
DEVA MEMORY MENU This is a new menu that appears in the software but is
currently inactive. It includes the buttons: SAVE DEVA STATE (which will allow you to
save all the Deva parameters), RESTORE DEVA STATE (will allow you to recall any of
the saved ‘states’), RESTORE DEFAULTS, and UPDATE SOFTWARE (this will allow
you to update software with out the auto-install program)
TIME CODE CHANGES (11.6) The TOGGLE USER BITS / TIMECODE button is now
called TOGGLE TC TYPE and now has a third option called JAM TIME OF DAY /
ENTER TIME OF DAY. DEVA has 2 clocks, a time code clock and a time of day clock.