Owner`s manual
Deva IV and Deva V Owner’s Manual
Chapter 3
17
generated by DEVA. The Reader T.C. field displays the estimated frame rate of timecode entering the
DEVA.
Time Code Out
Time Code Out toggles between Generator and Disk. Generator
outputs TC from the internal generator.
Disk outputs time code from the hard drive, or the disk which is selected for playback.
Time Code Run Mode
Time Code Run Mode toggles between F
ree Run, Record Run, C. JAM ALL, C. JAM T.C., and C. JAM U.B.
modes.
Free Run
In the Free Run mode, time code runs continuously fr
om either 00:00:00:00: or whatever valid time
code number you enter, since you can also jam time code from the DEVA's ’Time of Day’ clock.
Record Run
In the Record Run mode, time code starts and stops as you Record and Stop.
C. JAM ALL
The C. JAM All mode continuously Jams Time code and User Bits from an External Source.
C. JAM T.C.
The C. JAM T.C. mode continuously jams only the time code. The user bits can be set independently.
C. JAM. U.B.
The C. JAM U.B. mode continuously jams the User Bit
s, while the time code FREE RUNS indepen-
dently. This mode allows a second time code to be in
put as user bits from an external source.
Frame Rate
The Frame Rate button toggles the between all available time code frame rates. Available frame rates
in
clude: 30 NDF (Non Drop Frame), 30 DF, 23.98, 24, 25, 29.97 NDF, and 29.97 DF.
Time Code Reference
The Time Code Reference button toggles between XTAL and AES reference sources for the time code
generator
.
XTAL
Use the XTAL option when you want to use the Internal Crystal.
AES
AES for external reference from a digital source.
Important: This button has no effect. For recording leave this setting at XTAL, even if you are recording from an
external AES source such as Cameo. Timecode is always referenced to the internal DEVA sample rate
clock which may be locked to the DEVA’s internal oscillator or an external AES reference.
Toggle Time Code Type