10. In the Trim Calibrate menu select Go Now.
11. Press the STAR KEY.
12. The Go Now text will change to "---" indicating the Calibration has started.
13. Quickly press BACK (HP) knob to get back to the home screen (the one containing 2 outs and 6 input meters).
14. Let Nomad sit for about 2 to 4 minutes. You should see levels on the input meters creeping up every second
as it calibrates the input trim level.
15. You will see “Calibration Complete” message and tone will shut off when the process is done.
16. Cycle power, turn on tone and check to insure the trims work. With Nomad output level still set at -10dBu
and the trim set zero the input meter should show the tone at -30dB (plus or minus 1dB).
17. Move the cables to connect Output 1 to XLR input 3 and Output 2 to XLR Input 4.
18. Go to the Advanced Menu choose IN 3, 4 selection in the TRIM CAL CHANS menu and repeat the process 10
through 16.
19. Go to the Advanced Menu choose IN 5, 6 and repeat steps 10 through 16.
When done, if tone is inputted at -20dB (with the output levels set to 0dBu) and the Trim set to 0, the input meters
should read close to -20dB.