Battery Type Set
This menu is used for a TRX to send battery data to a QRX receiver and is not applicable in the ZFR.
Recording Mode Set
Record mode sets what the ZFR will do after you reach the file capacity of the card. Regardless of this
setting the card will only hold 256 files.
• NON-LOOP RECORD (recommended setting) - Once the card has filled up, recording will stop and FULL
will be displayed. This prevents over-writing any portion of the audio.
• LOOP RECORD - Once the card has filled up, the new audio will begin over-writing the oldest audio on
the card.
Allow IFB Remote Control
If IFB remote control is set to on the ZFR will accept remote roll and gain changes commands via ZaxNet. If
IFB remote control is set to off the ZFR will not receive any ZaxNet commands.
Please note that if the ZFR is transmitting ZaxNet it will not receive remote control commands regardless
of this setting.
Low Battery Stop Set
Low battery stop allows you to set the amount of time, after a low battery warning occurs, the on-board
recorder will close the current file and stop recording.
This is to prevent possible file corruption if the unit powers off and on due to a dead battery.
• NEVER STOP - The ZFR will not stop recording unless manually stopped or the battery dies.
• Any interval from 1 to 99 minutes - once the battery indicator starts blink a low battery warning the
ZFR will continue to record for the time set in the menu - then it will close the file and stop recording.
BATTERY TYPE:
NIMH QRX
RECORD MODE:
LOOP RECORD
LOW BATT STOP:
NEVER STOP
LOW BATT STOP:
5 MINUTES
ALLOW IFB REMOTE
CONTROL: ON