Produkte Products Prüfbericht-Nr.: Test Report No.: 50250100 001 Auftrags-Nr.: Order No.: Kunden-Referenz-Nr.: Client Reference No.: N/A Auftragsdatum: 17. 05. 2019 Order date: Auftraggeber: Client: Shenzhen Mazepower Technology Ltd. Room 707, 7/F, Tower A, Da Tang Shi Dai Building, No.2203 Meilong Avenue, Long Hua District, ShenZhen, China Prüfgegenstand: Test item: USB C PD Wall Charger 168116052 Seite 1 von 61 Page 1 of 61 Bezeichnung / Typ-Nr.: MZ30PD, MZ18PD Identification / Type No.
www.tuv.com Page 2 of 61 Report No.: 50250100 001 TEST REPORT IEC 60950-1 Information technology equipment – Safety – Part 1: General requirements Report Number........................... : Date of issue.............................. : 50250100 001 See cover page Total number of pages................. See cover page Applicant’s name ....................... : See cover page Address..................................... : See cover page Test specification: Standard....................................
www.tuv.com Page 3 of 61 Report No.: 50250100 001 Test item description.................... : USB C PD Wall Charger Trade Mark .................................. : No trademark used on the product Manufacturer ............................... : Same as applicant. Model/Type reference ................... : 1) MZ30PD, 2) MZ18PD Ratings........................................ : Input: 100-240Vac, 50/60Hz, 600mA Output: 1) DC5V/3A; DC9V/3A; DC12V/2.5A; DC15V/2A; DC20V/1.5A 2) DC5V/3A; DC9V/2A; DC12V/1.
www.tuv.com Page 4 of 61 Report No.: 50250100 001 List of Attachments (including a total number of pages in each attachment): - see cover page Summary of testing: Tests performed (name of test and test clause): Testing location: 1. Max. ambient temperature +25°C. See cover page 2. Following tests performed during evaluation Clause(s) Test(s) 1.6.2 1.7.11 2.1.1.1 2.1.1.5 2.2.2 2.4 2.5 2.9.2 2.10.2 2.10.3 & 2.10.4 4.2.4 4.2.6 4.2.7 4.3.6 4.5.2 4.5.5 5.1.6 5.2 5.
www.tuv.com Copy of marking plate: TRF No. IEC60950_1F Page 5 of 61 Report No.
www.tuv.com Page 6 of 61 Report No.: 50250100 001 Test item particulars......................................... : Equipment mobility.................................................: [] movable [] hand-held [] transportable [] stationary [] for building-in [x] direct plug-in Connection to the mains........................................
www.tuv.com Page 7 of 61 Report No.: 50250100 001 Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided ....................................................
www.tuv.com Page 8 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 1 GENERAL P 1.5 Components P 1.5.1 General P Comply with IEC 60950-1 or relevant component standard (see appended tables 1.5.1) P 1.5.2 Evaluation and testing of components Components which are certified to IEC and/or national standards are used correctly within their ratings. Components not covered by IEC standards are tested under the conditions present in the equipment.
www.tuv.com Page 9 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 1.6.1 AC power distribution systems TN power system P 1.6.2 Input current Highest load according to 1.2.2.1 for this equipment is the operation with the maximum specified by the manual instruction. (see appended table 1.6.2) P 1.6.3 Voltage limit of hand-held equipment This appliance is not handheld equipment. 1.6.
www.tuv.com Page 10 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 1.7.2.5 Operator access with a tool No operator accessible area that needs to be accessed by the use of a tool. N/A 1.7.2.6 Ozone Not such equipment. N/A 1.7.3 Short duty cycles Equipment is designed for continuous operation. N/A 1.7.4 Supply voltage adjustment .............................. : No voltage selector.
www.tuv.com Page 11 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 1.7.14 Equipment for restricted access locations.......... : 2 PROTECTION FROM HAZARDS P 2.1 Protection from electric shock and energy hazards P 2.1.1 Protection in operator access areas No access with test finger and test pin to any hazardous parts. P 2.1.1.1 Access to energized parts See above. P Test by inspection ........................................... : See above.
www.tuv.com Page 12 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark 2.2 SELV circuits 2.2.1 General requirements 2.2.2 Voltages under normal conditions (V) ................: Between any conductors of the SELV circuits 42.4 V peak or 60 V d.c. are not exceeded. Verdict P The secondary circuits were tested as SELV. See 2.2.2 to 2.2.4. P P See appended table 2.2. 2.2.3 Voltages under fault conditions (V) ....................
www.tuv.com Page 13 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict Measured voltage (V)....................................... : <450Vpeak ¾ Measured circuit capacitance (nF or µF) ............. : CY1= 470pF ¾ 2.4.3 Connection of limited current circuits to other circuits P 2.5 Limited power sources Output circuit as limited current circuit connected to primary via bridging capacitors (CY1).
www.tuv.com Page 14 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 2.6.4.1 General N/A 2.6.4.2 Protective earthing and bonding terminals N/A Rated current (A), type, nominal thread diameter (mm) .............................................................: ¾ 2.6.4.3 Separation of the protective earthing conductor from protective bonding conductors N/A 2.6.5 Integrity of protective earthing N/A 2.6.5.1 Interconnection of equipment N/A 2.
www.tuv.com Page 15 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 2.8 Safety interlocks 2.8.1 General principles N/A 2.8.2 Protection requirements N/A 2.8.3 Inadvertent reactivation N/A 2.8.4 Fail-safe operation N/A Protection against extreme hazard N/A 2.8.5 Moving parts N/A 2.8.6 Overriding N/A 2.8.7 Switches, relays and their related circuits N/A 2.8.7.1 Separation distances for contact gaps and their related circuits (mm) ..
www.tuv.com Page 16 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 2.10.1.6 Special separation requirements Not applied. N/A 2.10.1.7 Insulation in circuits generating starting pulses No such circuit. N/A 2.10.2 Determination of working voltage 2.10.2.1 General P The rms and the peak voltage were measured with unit connected to a 240V TN power system. P The input neutral and secondary minus pole were connected during measurement.
www.tuv.com Page 17 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark b) Transients from a telecommunication network : Verdict N/A 2.10.4 Creepage distances See appended table 2.10.3 and 2.10.4. P 2.10.4.1 General CTI rating for all materials of minimum 100. P 2.10.4.2 Material group and comparative tracking index P CTI tests ........................................................ : Material group IIIb is assumed to be used. ¾ 2.10.4.
www.tuv.com Page 18 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Routine test 2.10.5.14 Additional insulation in wound components Verdict N/A No such construction. N/A Working voltage ............................................. : N/A - Basic insulation not under stress ..................... : N/A - Supplementary, reinforced insulation ............... : N/A 2.10.6 Construction of printed boards See below. P 2.10.6.
www.tuv.com Page 19 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 3.1.3 Securing of internal wiring The internal wires are secured by soldering and glue on PCB, so that a loosening of the terminal connection is unlikely. P 3.1.4 Insulation of conductors The insulation of the individual conductors suitable for the application and the working voltage. P 3.1.5 Beads and ceramic insulators Not used. N/A 3.1.
www.tuv.com Page 20 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict Mass of equipment (kg), pull (N) ......................: ¾ Longitudinal displacement (mm) .......................: ¾ 3.2.7 Protection against mechanical damage N/A 3.2.8 Cord guards N/A Diameter or minor dimension D (mm); test mass (g) .....................................................................: ¾ Radius of curvature of cord (mm).......................: ¾ 3.2.
www.tuv.com Page 21 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 3.4.8 Switches as disconnect devices N/A 3.4.9 Plugs as disconnect devices N/A 3.4.10 Interconnected equipment Not interconnected equipment. N/A 3.4.11 Multiple power sources Only one supply connection provided. N/A 3.5 Interconnection of equipment 3.5.1 General requirements 3.5.2 Types of interconnection circuits .......................
www.tuv.com Page 22 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 4.2.6 Drop test; height (mm) ..................................... : The power supply has been subjected to 3 drops from 1 m height on a hard wooden surface. P 4.2.7 Stress relief test After the test at temperature of 116°C, no shrinkage, distortion or loosening of any enclosure part was noticeable on the equipment. P 4.2.8 Cathode ray tubes No CRT in the unit.
www.tuv.com Page 23 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict - Excessive discharging rate for any battery N/A 4.3.9 Oil and grease N/A 4.3.10 Dust, powders, liquids and gases Equipment in intended use not considered to be exposed to these. N/A 4.3.11 Containers for liquids or gases No container for liquid or gas. N/A 4.3.12 Flammable liquids .......................................... : No such flammable liquid.
www.tuv.com Page 24 of 61 Report No.: 50250100 001 IEC 60950-1 Clause 4.4.5.1 Requirement + Test 4.4.5.3 Verdict General N/A Not considered to cause pain or injury. A)……….: N/A Is considered to cause pain, not injury. B) ………: N/A C) ………: N/A Considered to cause injury. 4.4.5.2 Result - Remark Protection for users N/A Use of symbol or warning …………………………: N/A Protection for service persons N/A Use of symbol or warning …………………………: N/A 4.5 Thermal requirements P 4.5.
www.tuv.com Page 25 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict Conditioning temperature (°C), time (weeks)....... : ¾ 4.7 Resistance to fire P 4.7.1 Reducing the risk of ignition and spread of flame No excessive temperatures. No easily burning materials employed. Fire enclosure provided. Method 1, selection and application of components (see appended table 4.
www.tuv.com Page 26 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark EUT has only one mains connection. Verdict 5.1.2 Configuration of equipment under test (EUT) P 5.1.2.1 Single connection to an a.c. mains supply 5.1.2.2 Redundant multiple connections to an a.c. mains supply N/A 5.1.2.3 Simultaneous multiple connections to an a.c. mains supply N/A 5.1.3 Test circuit Equipment of figure 5A used. P 5.1.
www.tuv.com Page 27 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark b) EUT whose telecommunication ports have no reference to protective earth Verdict N/A 5.2 Electric strength P 5.2.1 General (see appended table 5.2) P 5.2.2 Test procedure (see appended table 5.2) P 5.3 Abnormal operating and fault conditions 5.3.1 Protection against overload and abnormal operation (see appended table 5.3) 5.3.2 Motors No motors. 5.3.
www.tuv.com Page 28 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 6.1.2.2 Exclusions ....................................................: N/A 6.2 Protection of equipment users from overvoltages on telecommunication networks N/A 6.2.1 Separation requirements 6.2.2 Electric strength test procedure N/A N/A 6.2.2.1 Impulse test (see appended table 5.2) N/A 6.2.2.2 Steady-state test (see appended table 5.2) N/A 6.2.2.
www.tuv.com Page 29 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict A.1.5 Test procedure N/A A.1.6 Compliance criteria N/A Sample 1 burning time (s)................................ : ¾ Sample 2 burning time (s)................................ : ¾ Sample 3 burning time (s)................................ : ¾ A.
www.tuv.com Page 30 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict B.3 Maximum temperatures N/A B.4 Running overload test N/A B.5 Locked-rotor overload test N/A Test duration (days) ....................................... : ¾ Electric strength test: test voltage (V) ................ : ¾ N/A B.6 Running overload test for d.c. motors in secondary circuits B.6.1 General N/A B.6.2 Test procedure N/A B.6.
www.tuv.com Page 31 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict E ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13) F ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES (see 2.10 and Annex G) G ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES N/A G.1 Clearances N/A G.1.1 General N/A G.1.2 Summary of the procedure for determining minimum clearances N/A G.2 Determination of mains transient voltage (V) N/A G.2.
www.tuv.com Page 32 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict K.1 Making and breaking capacity N/A K.2 Thermostat reliability; operating voltage (V) ....... : N/A K.3 Thermostat endurance test; operating voltage (V) .................................................................... : N/A K.4 Temperature limiter endurance; operating voltage (V) ............................................................... : N/A K.
www.tuv.com Page 33 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict N.2 IEC 60065 impulse test generator N/A P ANNEX P, NORMATIVE REFERENCES Q ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1) N/A - Preferred climatic categories ......................... : N/A - Maximum continuous voltage ........................ : N/A - Combination pulse current ............................ : N/A Body of the VDR Test according to IEC60695-11-5.......
www.tuv.com Page 34 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict W.1 Touch current from electronic circuits N/A W.1.1 Floating circuits N/A W.1.2 Earthed circuits N/A W.2 Interconnection of several equipments N/A W.2.1 Isolation N/A W.2.2 Common return, isolated from earth N/A W.2.3 Common return, connected to protective earth N/A X ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause C.1) N/A X.
www.tuv.com Page 35 of 61 Report No.: 50250100 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict EE ANNEX EE, Household and home/office document/media shredders N/A EE.1 General N/A EE.2 Markings and instructions N/A Use of markings or symbols…………………………: N/A Information of user instructions, maintenance and/or servicing instructions…………………………: N/A EE.3 Inadvertent reactivation test…………………………: N/A EE.
www.tuv.com 1.5.1 Page 36 of 61 Report No.: 50250100 001 TABLE: List of critical components Object/part No. ManuFacturer/ trademark Type/model P Technical data Standard (Edition / year) US plug Shenzhen Mazepower Technology Ltd. -- PCB Interchangeable Interchangeable V-1 or better, min. 130ºC UL 796 UL Plug holder CHI MEI CORPORATION PC-6610 PC, V-0, 115°C, Min. thickness: 1.5mm UL 94 UL E56070 Material of enclosure CHI MEI CORPORATION PC-6610 PC, V-0, 115°C, Min. thickness: 1.
www.tuv.com --Magnet wire SHANTOU SHENGANG ELECTRISAL INDUSTRIAL CO LTD Page 37 of 61 Report No.: 50250100 001 xUEW/130 130°C CYG-ZHP, CBTT-L, CB-TT-S, CB-TT-T Min. 125°C, VW- UL 224 1 UL E180908 GCE(Dongguan) G Y1 Electronics Co Ltd 400VAC, 470pF, UL 60384-14 125°C, Y1 UL E464834 Non-Optical Isolator (U1) POWER INTEGRATIONS INC INN3267C Ext. Cr./cl≥ 7.0mm, 110°C UL 1577 UL E358471 (Alternative) POWER INTEGRATIONS INC INN3268C Ext. Cr./cl≥ 7.
www.tuv.com Capacitor (EC1) Page 38 of 61 Report No.: 50250100 001 appliance 105°C Electrolytic Interchangeable Capacitor (EC2) Interchangeable Min. 400V, 33uF, UL 60950-1 105°C Tested with appliance Bridge Rectifier (DB1) Interchangeable Interchangeable Min. 1000V, Min. UL 60950-1 3A Tested with appliance Q1 Interchangeable Interchangeable Min. 160V, Min 600mA UL 60950-1 Tested with appliance R47 Interchangeable Interchangeable 4.7KΩ, 0.
www.tuv.com 1.6.2 Page 39 of 61 Report No.: 50250100 001 TABLE: Electrical data (in normal conditions) P U (V/Hz) I (A) Irated (A) P (W) Fuse # Ifuse (A) 90V/50Hz 0.381 -- 19.0 F1 0.381 90V/60Hz 0.374 -- 19.1 F1 0.374 100V/50Hz 0.356 0.6 19.0 F1 0.356 100V/60Hz 0.346 0.6 19.0 F1 0.346 240V/50Hz 0.159 0.6 18.9 F1 0.159 240V/60Hz 0.168 0.6 19.0 F1 0.168 264V/50Hz 0.147 -- 19.1 F1 0.147 264V/60Hz 0.157 -- 19.1 F1 0.157 90V/50Hz 0.592 -- 32.5 F1 0.
www.tuv.com Page 40 of 61 Report No.: 50250100 001 100V/60Hz 0.586 0.6 33.8 F1 0.586 240V/50Hz 0.295 0.6 33.7 F1 0.295 240V/60Hz 0.287 0.6 33.7 F1 0.287 264V/50Hz 0.266 -- 33.8 F1 0.266 264V/60Hz 0.264 -- 33.8 F1 0.264 Supplementary information: measured current at rated voltage did not exceed Irated by +10%. P 2.1.1.5 c) 1) TABLE: max. V, A, VA test Voltage (rated) (V) Current (rated) (A) Voltage (max.) (V) Current (max.) (A) VA (max.) (VA) 5 3.0 5.09 3.50 16.
www.tuv.com 2.5 Page 41 of 61 Report No.: 50250100 001 TABLE: Limited power sources P Circuit output tested: Note: Measured Uoc (V) with all load circuits disconnected: Components Test condition Uoc (V) Isc (A) (Single fault) Meas. USB Output terminal Normal VA Limit Meas. Limit 5.09 3.50 8 16.84 100 9.02 3.48 8 30.55 100 12.03 2.92 8 34.46 100 15.11 2.34 8 34.42 100 19.63 1.91 8 35.53 100 0 0 8.0 0 100 (5Vdc, 3A) Normal (9Vdc, 3A) Normal (12Vdc, 2.
www.tuv.com 2.10.3 and 2.10.4 Page 42 of 61 Report No.: 50250100 001 TABLE: Clearance and creepage distance measurements Clearance (cl) and creepage distance (cr) at/of/between: U peak (V) U r.m.s. (V) P Required cl (mm) cl (mm) Required cr (mm) cr (mm) L trace and N trace before fuse F1 (F*) 420 250 1.5 2.6 2.5 2.6 Trace of fuse F1 (F*) 420 250 1.5 2.8 2.5 2.8 LF1 to accessible enclosure (R*) 420 250 4.0 5.6 5.0 5.
www.tuv.com 4.5 Page 43 of 61 Report No.: 50250100 001 TABLE: Thermal requirements P Supply voltage (V) ...................... Test A: 90V, 60Hz Horizontal ¾ Test B: 90V, 60Hz Vertical Test C: 264V, 50Hz Horizontal Test D: 264V, 50Hz Vertical Ambient Tmin (°C) ........................-- -- -- -- ¾ Ambient Tmax (°C) ........................-- -- -- -- ¾ Maximum measured temperature T of part/at:: T (°C) Allowed Tmax (°C) A B C D -- Plug holder (inside) 59.0 60.6 55.6 56.
www.tuv.com 4.5 Page 44 of 61 Report No.: 50250100 001 TABLE: Thermal requirements P Supply voltage (V) ...................... Test A: 90V, 60Hz Horizontal ¾ Test B: 90V, 60Hz Vertical Test C: 264V, 50Hz Horizontal Test D: 264V, 50Hz Vertical Ambient Tmin (°C) ........................-- -- -- -- ¾ Ambient Tmax (°C) ........................-- -- -- -- ¾ Maximum measured temperature T of part/at:: T (°C) Allowed Tmax (°C) A B C D -- Plug holder (inside) 59.4 60.1 54.5 55.
www.tuv.com 4.5 Page 45 of 61 Report No.: 50250100 001 TABLE: Thermal requirements P Supply voltage (V) ...................... Test A: 90V, 60Hz Horizontal ¾ Test B: 90V, 60Hz Vertical Test C: 264V, 50Hz Horizontal Test D: 264V, 50Hz Vertical Ambient Tmin (°C) ........................-- -- -- -- ¾ Ambient Tmax (°C) ........................-- -- -- -- ¾ Maximum measured temperature T of part/at:: T (°C) Allowed Tmax (°C) A B C D -- Plug holder (inside) 60.3 58.5 60.8 64.
www.tuv.com 4.5.5 Page 46 of 61 Report No.: 50250100 001 TABLE: Ball pressure test of thermoplastic parts P Allowed impression diameter (mm) .................. : £ 2 mm ¾ Test temperature Impression diameter (°C) (mm) Part Plug pin holder 125 1.12 Note(s): For bobbin material used in transformer T1 which is phenolic material, it is acceptable without test., see table 1.5.1. 4.
www.tuv.com 5.3 Page 47 of 61 Report No.: 50250100 001 TABLE: Fault condition tests P -- ¾ Power source for EUT: ManuFacturer, model/type, output rating ................................................ : Component Fault Supply vol- Test time Fuse no. No.
www.tuv.com Page 48 of 61 Report No.: 50250100 001 R9 SC 240 10 mins F1 0.01 Unit shut down immediately; No damaged, no hazard. EC5 SC 240 10 mins F1 0.01 Unit shut down immediately; No damaged, no hazard. R21 SC 240 10 mins F1 0.287 Normal work, no change, No damaged, no hazard. Output SC 240 10 mins F1 0.01 Unit shut down immediately; No damaged, no hazard. Output O-L 240 5hour 30mins F1 0.292 to 0.301 to 0.308 to Temperature was stable at 3.45A, increase to 3.
www.tuv.com C.2 Loc. Page 49 of 61 TABLE: transformers T1 Tested insulation Working voltage peak / V (2.10.2) Working voltage rms / V (2.10.2) Report No.: 50250100 001 Required Required Required electric clearance / creepage strength mm distance / mm (5.2) (2.10.3) (2.10.4) Primary RI winding to secondary pin 428 250 3000V 4.2 5.0 Core to RI secondary pin Loc. Tested insulation 428 250 3000V 4.2 5.
www.tuv.com Page 50 of 61 C.2 TABLE: transformers T1 Transformer Note: pin 6 was cut off, 2/3 of pin 5 was cut off. TRF No. IEC60950_1F Report No.
www.tuv.com Page 51 of 61 Report No.: 50250100 001 National Differences Clause Requirement + Test Result - Remark Verdict ATTACHMENT TO TEST REPORT IEC 60950-1 with A1:2009 and A2:2013 CANADA NATIONAL DIFFERENCES Information technology equipment – Safety – Part 1: General requirements Differences according to............. : CAN/CSA-C22.2 No. 60950-1-07, Amd 1:2011, Amd 2:2014 Attachment Form No. ................. : Attachment Originator................ : CA_ND_IEC60950_1F CSA Master Attachment ....
www.tuv.com Page 52 of 61 Report No.: 50250100 001 National Differences Clause Requirement + Test 1.7.7 Wiring terminals intended to supply Class 2 outputs in accordance with CEC Part 1 or NEC shall be marked with the voltage rating and “Class 2” or equivalent. Marking shall be located adjacent to the terminals and shall be visible during wiring. Where a fuse is used to provide Class 2, Limited Not used for such kind of Power Source, or TNV current limiting, it shall not equipment.
www.tuv.com Page 53 of 61 Report No.: 50250100 001 National Differences Clause Requirement + Test Result - Remark 3.3.3 Wire binding screws are not permitted to attach conductors larger than 10 AWG (5.3 mm2). Terminals for permanent wiring, including protective earthing terminals, are required to be suitable for US/Canadian wire gauge sizes, rated 125 percent of the equipment rating, and be specially marked when specified (1.7.7).
www.tuv.com Page 54 of 61 Report No.: 50250100 001 National Differences Clause Requirement + Test Result - Remark Verdict OTHER DIFFERENCES The following key national differences are based on requirements other than national regulatory requirements. 1.5.1 1.6.1.2 2.3.1 2.3.2.1 2.6.2 2.6.3.
www.tuv.com Page 55 of 61 Report No.: 50250100 001 National Differences Clause Requirement + Test Result - Remark 4.2.8.1 Enclosures around CRTs with a face diameter of 160 mm or more are required to reduce the risk of injury due to the implosion of the CRT. Equipment with handles complies with special loading tests. Battery packs for both portable and stationary applications are required to comply with special component requirements.
www.tuv.com Page 56 of 61 Report No.: 50250100 001 National Differences Clause Requirement + Test Result - Remark Verdict ATTACHMENT TO TEST REPORT IEC 60950-1 with A1: 2009 and A2:2013 U.S.A. NATIONAL DIFFERENCES Information technology equipment – Safety – Part 1: General requirements Differences according to.............. : UL 60950-1-07(Second Edition) + A1: 2011 + A2: 2014 Attachment Form No. .................. : US_ND_IEC60950_1F Attachment Originator ................. : UL Master Attachment ...
www.tuv.com Page 57 of 61 Report No.: 50250100 001 National Differences Clause 1.7.
www.tuv.com Page 58 of 61 Report No.: 50250100 001 National Differences Clause Requirement + Test Result - Remark Verdict Minimum cord length is 1.5 m, with certain constructions such as external power supplies allowed to consider both input and output cord lengths into the requirement N/A Flexible power supply cords are compatible with Article 400 of the NEC, and Tables 11 and 12 of the CEC N/A 3.2.9 Permanently connected equipment has a suitable wiring compartment and wire bending space 3.
www.tuv.com Page 59 of 61 Report No.: 50250100 001 National Differences Clause Requirement + Test 4.7 For computer room applications, automated Not such an application. information storage systems with combustible media greater than 0.76 m 3 (27 cu ft) have a provision for connection of either automatic sprinklers or a gaseous agent extinguishing system with an extended discharge N/A 4.7.3.1 For computer room applications, enclosures with Not such an application.
www.tuv.com Page 60 of 61 Report No.: 50250100 001 National Differences Clause Requirement + Test Result - Remark 1.6.1.2 A circuit for connection to the DC Mains Supply is classified as a SELV Circuit, TNV-2 Circuit or Hazardous Voltage Circuit depending on the maximum operating voltage of the supply No connection to the DC Mains Supply.
www.tuv.com Page 61 of 61 Report No.: 50250100 001 National Differences Clause Requirement + Test Result - Remark Verdict 6.4 Equipment intended for connection to telecommunication network outside plant cable is protected against overvoltage from power line crosses in accordance with 6.4 and Annex NAC No TNV circuits. N/A Annex EE Articulated accessibility probe (Fig EE.3) is used for Not such equipment.
Attachment 1 www.tuv.com Page 1 of 6 Report No.: 50250100 001 Plug National Deviation evaluated based on UL1310 43 - Direct Plug-In Blade Securement Test Displacement (mm) Model: MZ30PD Pin holder type: PC-6610, mfr.: CHI MEI CORPORATION Blade 1 Blade 2 Grounding Pin Blade 1 and 2 0.20 0.20 -- 0.15 Note: 1) The blades did not loosen by more than 2.4 mm or pull out. 44 - Direct Plug-In Security of Input Contacts Displacement (mm) Model: MZ30PD Blade 1 Blade 2 Both Blades 0.1 0.1 0.1 0.
Attachment 1 www.tuv.com Page 2 of 6 Report No.: 50250100 001 46.4 - Direct Plug-In Rod Pressure Test Model: MZ30PD Rod Pressure Point Pin holder type: PC6610, mfr.: CHI MEI CORPORATION Center of enclosure face closest to transformer Voltage Touch Current (Vpk) Required? 28.6 No Note: -- Single-Phase Equipment - Figure 5a. The test was made in all combinations to the normal and reverse polarity of the supply circuit (Polarity Switch P1).
Attachment 1 www.tuv.com Page 3 of 6 Report No.: 50250100 001 7.11-Weight and moment determination: (Direct Plug-In Unit) METHOD The output cord was not included in the weight measurement. Each sample was weighed and the distance to the center of gravity was measured using suitable instruments. The distance between the center of the blades and the center of gravity was measured. The moments were then calculated by taking the products of the above measurements. W = Weight of the device.
Attachment 1 www.tuv.com Page 4 of 6 Report No.: 50250100 001 7.12 Distance from plug to accessible enclosure surface The enclosure of a unit shall be capable of being gripped for removal from the receptacle to which it is connected, and the perimeter of the face section from which the blades project shall not be less than 0.20 inch (5.1 mm) from any point on either blade A: 14.
Attachment 1 www.tuv.com Page 5 of 6 Report No.
Attachment 1 www.tuv.com Page 6 of 6 Report No.: 50250100 001 North American integrated plug according to ANSI/NEMA WD 6, FIGURE 1-15 Part No. Dimensions Limit (mm) Verdict 1.41 1.52 (TYP.) (1.393 – 1.647) P 6.24 6.10 – 6.60 P Measurem ent (m m ) Non Polarity only A. Thickness of live pin B. Width of live pin C. Distance between two live pins (centre) 12.59 12.7 (12.573 – 12.827) P D. Distance between hole centre and plug face (if hole used) 12.14 11.405 – 12.167 P E.
Attachment 2 Photo Documentation Page 1 of 11 Product: USB C PD Wall Charger Type Designation: MZ30PD, MZ18PD Figure 1. External view Figure 2. External view Rev. 0 Report No.
Attachment 2 Photo Documentation Page 2 of 11 Product: USB C PD Wall Charger Type Designation: MZ30PD, MZ18PD Figure 3. External view Figure 4. Inside view Rev. 0 Report No.
Attachment 2 Photo Documentation Page 3 of 11 Product: Report No.: 50250100 001 USB C PD Wall Charger Type Designation: MZ30PD, MZ18PD Figure 5. Inside view Figure 6. Inside view of plug holder Rev.
Attachment 2 Photo Documentation Page 4 of 11 Product: Report No.: 50250100 001 USB C PD Wall Charger Type Designation: MZ30PD, MZ18PD Figure 7. Components side view Figure 8. PCB trace side view Rev.
Attachment 2 Photo Documentation Page 5 of 11 Product: Report No.: 50250100 001 USB C PD Wall Charger Type Designation: MZ30PD, MZ18PD Figure 9. Top view of transformer T1 Figure 10. Bottom view of transformer T1 Rev.
Attachment 2 Photo Documentation Page 6 of 11 Product: Report No.: 50250100 001 USB C PD Wall Charger Type Designation: MZ30PD, MZ18PD Figure 11. Inside view of transformer T1 Figure 12. Inside view of transformer T1 (N5) Rev.
Attachment 2 Photo Documentation Page 7 of 11 Product: Report No.: 50250100 001 USB C PD Wall Charger Type Designation: MZ30PD, MZ18PD Figure 13. Inside view of transformer T1 (N5) Figure 14. Inside view of transformer T1 (N4) Rev.
Attachment 2 Photo Documentation Page 8 of 11 Product: Report No.: 50250100 001 USB C PD Wall Charger Type Designation: MZ30PD, MZ18PD Figure 15. Inside view of transformer T1 (N4) Figure 16. Inside view of transformer T1 (N3) Rev.
Attachment 2 Photo Documentation Page 9 of 11 Product: Report No.: 50250100 001 USB C PD Wall Charger Type Designation: MZ30PD, MZ18PD Figure 17. Inside view of transformer T1 (N3) Figure 18. Inside view of transformer T1 (N2) Rev.
Attachment 2 Photo Documentation Page 10 of 11 Product: Report No.: 50250100 001 USB C PD Wall Charger Type Designation: MZ30PD, MZ18PD Figure 19. Inside view of transformer T1 (N1) Figure 20. Inside view of transformer T1 (N1) Rev.
Attachment 2 Photo Documentation Page 11 of 11 Product: Report No.: 50250100 001 USB C PD Wall Charger Type Designation: MZ30PD, MZ18PD Figure 21. Bobbin view of transformer T1 (N1) Rev.
Attachment 3 Produktsicherheit und –qualität Product Safety and Quality Page 1 of 2 Report no.: 50250100 001 Lab name: Shenzhen LCS Compliance Testing Laboratory Ltd. Instr. Instrument Instrument Range Used Make and Model Calibration Date ** Code I.D.
Attachment 3 Produktsicherheit und –qualität Product Safety and Quality LCS-S171 -- LCS-S015 -- LCS-S014 -- Page 2 of 2 Report no.: 50250100 001 High voltage >100MΩ, >25pF TEXAS 2018/10/10 probe of Oscillograph Temperature 98̚45%RH, -40̚ GUANGZHOU 2018/10/10 & Humidity GONGWEN/GDS100 oC Chamber 100 Electric 500-5KV(AC/DC) YANGZI 2018/10/10 Strength 0~100/20mA(AC/C) ELECTRONICS/Y tester D2673 2019/10/09 2019/10/09 2019/10/09 Name: Shenzhen LCS Compliance Testing Laboratory Ltd. Address: 1/F.