Safety Information

www.tuv.com
Page 14 of 61
Report No.: 50250100 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
2.6.4.1
General
N/A
2.6.4.2
Protective earthing and bonding terminals
N/A
Rated current (A), type, nominal thread diameter
(mm) .............................................................:
¾
2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
N/A
2.6.5
Integrity of protective earthing
N/A
2.6.5.1
Interconnection of equipment
N/A
2.6.5.2
Components in protective earthing conductors and
protective bonding conductors
N/A
2.6.5.3
Disconnection of protective earth
N/A
2.6.5.4
Parts that can be removed by an operator
N/A
2.6.5.5
Parts removed during servicing
N/A
2.6.5.6
Corrosion resistance
N/A
2.6.5.7
Screws for protective bonding
N/A
2.6.5.8
Reliance on telecommunication network or cable
distribution system
N/A
2.7
Overcurrent and earth fault protection in primary circuits
P
2.7.1
Basic requirements
The equipment relies on fuse
or circuit breaker of the wall
outlet protection of the building
installation in regard to L to N
short
-circuits and earth
fault
condition. A build
-in fuse
provided as overcurrent
protection device (see 5.3)
P
Instructions when protection relies on building
installation
Pluggable equipment type A.
N/A
2.7.2
Faults not simulated in 5.3.7
The protection devices are well
dimensioned and mounted.
P
2.7.3
Short-circuit backup protection
Building installation is
considered as providing short-
circuit backup protection.
P
2.7.4
Number and location of protective devices ..........:
Overcurrent protection by one
built-in current fuse.
P
2.7.5
Protection by several devices
Protection provided by one
fuse only.
N/A
2.7.6
Warning to service personnel ............................:
No service work necessary.
N/A