IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
b) EUT whose telecommunication ports have no
reference to protective earth
N/A
5.2
Electric strength
P
5.2.1
General
(see appended table 5.2)
P
5.2.2
Test procedure
(see appended table 5.2)
P
5.3
Abnormal operating and fault conditions
P
5.3.1
Protection against overload and abnormal
operation
(see appended table 5.3)
P
5.3.2
Motors
No motors.
N/A
5.3.3
Transformers
(see appended Annex C and
table 5.3)
P
5.3.4
Functional insulation ....................................... :
By short-circuited, results see
appended table 5.3.
P
5.3.5
Electromechanical components
No electromechanical
component .
N/A
5.3.6
Audio amplifiers in ITE ................................... :
Audio amplifiers not used.
N/A
5.3.7
Simulation of faults
(see appended table 5.3.)
P
5.3.8
Unattended equipment
No such equipment.
N/A
5.3.9
Compliance criteria for abnormal operating and
fault conditions
P
5.3.9.1
During the tests
No fire or molten metal
occurred and no deformation of
enclosure during the tests.
P
5.3.9.2
After the tests
No reduction of clearance and
creepage distance. Electric
strength test is made on basic,
supplementary and reinforced
insulation after test.
P
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1
Requirements
N/A
Supply voltage (V) .........................................:
¾
Current in the test circuit (mA) ........................:
¾