User's Manual

Hardware Installation
9
The Power Injector has no On/Off power switch. The Power Injector receives power and is
ready for AP-7131 device connection and operation as soon as AC power is applied.
The Power Injector demonstrates the following LED behavior under normal and/or problematic
operating conditions:
2.4 Mounting the AP-7131
The AP-7131 can attach to a wall, mount under a suspended T-Bar or above a ceiling (plenum or
attic). Choose one of the following mounting options based on the physical environment of the
coverage area. Do not mount the AP-7131 in a location that has not been approved in a site survey.
2.4.1 Wall Mounting
Wall mounting requires hanging the AP-7131 along its width (or length) using the pair of slots on the
bottom of the unit and using the AP-7131 itself as a mounting template for the screws.
The hardware and tools (customer provided) required to install the AP-7131 on a wall consists of:
Two Phillips pan head self-tapping screws
(ANSI Standard) #6-18 X 0.875in. Type A or AB Self-Tapping screw, or
(ANSI Standard Metric) M3.5 X 0.6 X 20mm Type D Self-Tapping screw
Two wall anchors
Wall mount template (included on the next page)
Security cable (optional)
LED AC (Main) Port
Green (Steady) Power Injector is receiving
power from AC outlet
Indicates a device is
connected to the
Power Injector’s outgoing
Data & Power cable
Green (Blinking) Output voltage source is out
of range
The Power Injector is
overloaded or has a
short circuit
CAUTION An AP-7131 should be wall mounted to concrete or plaster-wall-board
(dry wall) only. Do not wall mount an AP-7131 to combustible
surfaces.
!