User's Manual
Hardware Installation
9
The Power Injector has no On/Off power switch. The Power Injector receives power and is
ready for AP-7131 device connection and operation as soon as AC power is applied.
The Power Injector demonstrates the following LED behavior under normal and/or problematic
operating conditions:
2.4 Mounting the AP-7131
The AP-7131 can attach to a wall, mount under a suspended T-Bar or above a ceiling (plenum or
attic). Choose one of the following mounting options based on the physical environment of the
coverage area. Do not mount the AP-7131 in a location that has not been approved in a site survey.
2.4.1 Wall Mounting
Wall mounting requires hanging the AP-7131 along its width (or length) using the pair of slots on the
bottom of the unit and using the AP-7131 itself as a mounting template for the screws.
The hardware and tools (customer provided) required to install the AP-7131 on a wall consists of:
• Two Phillips pan head self-tapping screws
(ANSI Standard) #6-18 X 0.875in. Type A or AB Self-Tapping screw, or
(ANSI Standard Metric) M3.5 X 0.6 X 20mm Type D Self-Tapping screw
• Two wall anchors
• Wall mount template (included on the next page)
• Security cable (optional)
LED AC (Main) Port
Green (Steady) Power Injector is receiving
power from AC outlet
Indicates a device is
connected to the
Power Injector’s outgoing
Data & Power cable
Green (Blinking) Output voltage source is out
of range
The Power Injector is
overloaded or has a
short circuit
CAUTION An AP-7131 should be wall mounted to concrete or plaster-wall-board
(dry wall) only. Do not wall mount an AP-7131 to combustible
surfaces.
!