User's Manual
AP 7161
Access Point Installation
Guide
11
Hardware Installation
Guidelines
CAUTION
All device wiring must comply with the National Electric Code
(NEC)
or regulations
and procedures defined by the regulatory bodies of the country or region
where the
devices are being deployed. All local building and structure codes must
be
observed.
WARNING!
Strictly
observe the following safety precautions and warnings when installing an AP
7161 access
point.
Precautions
Before installing an AP 7161 model access
point, verify the following grounding and lightning protection notes:
•
The
installation professional should be familiar with all grounding requirements and regional codes and ensure
that the access point and mounting asset are properly grounded. The grounding cable for an AP
7161
must
be
at a minimum a #10 gauge wire cross section. The cable can be attached to the unit using one of the
following
methods:
•
Loosen the grounding screw, insert the grounding cable into the hole below it,
and tighten the screw.
•
Loosen the grounding screw, wind the grounding cable around it,
and tighten the screw.
•
Attach a ring lug to the grounding cable and secure
it
to the unit using the grounding screw.
•
To properly attach the grounding cable to the access point, refer to AP
7161 Grounding Screw on page 17.
•
For Ethernet and lightning protection,
it
is recommended that a commercially available off-the-shelf
Lightning
Protection Unit
(LPU) be used on
all shielded CAT5E
Ethernet connections. The
LPU
should be rated for outdoor
use.
•
For
the best possible protection, each access point requires an
LPU
be installed adjacent to the access
point.
If there is a LAN connection to an indoor network, a second
LPU is required
at the cable entry point to the
building.
CAUTION
Lightning damage is not covered under the conditions of a standard
Motorola
Solutions product warranty. When installed correctly, Lightning Protection
Units (LPUs)
provide the best protection from the harmful effects of
lightning.
Observe all regional and national codes
that apply for lightning protection.
•
Verify that the deployment environment has a continuous temperature range compatible with the operating
temperature range of the device.