Vertical
Pole
Mount
Use the following procedures for vertical pole mount installations. Use of the extension arm is recommended
when mounting the access point to poles greater than 3 inches
is diameter.
For poles up to 3 inches in diameter when using a
U-bolt
:
1.
Thread the two inner nuts onto the U-bolt. Place the U-bolt at the desired mounting
location.
2.
Place the pole mount bracket section on the U bolt. Adjust the inner nuts until the pole mount bracket section
is
against the pole and the U-bolt can be secured
tightly to the pole.
3.
Place the angle adapter bracket section on the U-bolt with the open slot connections on the bottom and align
it
with the pole mount section.
4.
Put the two
outer nuts on the U-bolt to attach the angle adapter bracket section to the pole mount bracket
section.
5.
Tighten all nuts to 300 inch pounds
(lbf-in).
6.
Position the access point bracket section so that the bottom of the section
with the straight (not bevel cut) side
is oriented toward the bottom side of the AP
with the gore vent. Using a torque wrench or a ratchet and a
10mm socket, or an adjustable wrench, attach (but don’t tighten) the access point bracket section to the AP
7161 with the with four M6 hex flange screws.
7.
Insert two M6 hex flange screws into the bottom holes on the sides of the access
point bracket section.
8.
With the access point positioned so that the gore vent is facing down, insert the two M6 hex flange screws
in
the bottom holes on the sides of the access point bracket section into the open slot connections on
the bottom
of the angle adapter bracket section.
9.
Rotate the access point bracket section upward and align the top holes on the sides
with the top holes on the
angle adapter bracket section. Insert two M6 hex flange screws into the top holes on
the angle adapter bracket
section.
10.
Use a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, to finish attaching the access
point bracket section to the angle adapter bracket section with the M6 hex flange screws in the open
slot