User's Manual
26
AP 7161
Access Point Installation Guide
connections and the top holes on the angle adapter bracket section. Do not tighten the screws
until all rotation
and
tilt
adjustments are complete.
11.
To adjust the position of the
access point, rotate the access point bracket section (plus or minus 15 degrees)
and
tilt
the angle adapter bracket section (up to 45 degrees).
12.
Tighten all hex flange screws to 60 inch pounds
(lbf-in).
For mounting
with band clamps:
1.
Attach the pole mount bracket section at the desired mounting location using band clamps.
2.
With the angle adapter bracket section positioned so that the open connector slots are on
the bottom, attach
the angle adapter bracket section to the pole mount bracket section using two 1/2 inch bolts and nuts. Tighten
the nuts to 300 inch pounds
(lbf-in).
3.
Position the access point bracket section so that the bottom of the section with the straight (not bevel cut)
sides is oriented toward the bottom side of the AP
with the gore vent. Using a torque wrench or a ratchet and a
10mm socket, or an adjustable wrench, attach (but don’t tighten) the access point bracket section to the AP
7161 with the with four M6 hex flange screws.