User's Manual

12 AP-7602 Wireless Wallplate
To install the Power Injector to an Ethernet data source and an AP-7602:
1. Connect the Power Injector to an AC outlet (100VAC to 240VAC).
2. Connect an RJ-45 Ethernet cable between the Power Injector Data & Power Out
connector and the AP-7602’s GE1/POE port.
3. Connect an RJ-45 Ethernet cable between the network data supply (host) and the
Power Injector Data In connector.
Ensure the cable length from the Ethernet source (host) to the Power Injector and
AP-7602 does not exceed 100 meters (333 ft).
The Power Injector has no On/Off power switch. The Injector receives power and is
ready for device connection and operation as soon as AC power is applied. Refer to
the Installation Guide shipped with the Power Injector for a description of the LEDs.
2.5 Mounting Instructions
An AP-7602 can be mounted to a flat wall surface or over an existing telco junction box.
2.5.1 Wall Mount Procedure
To mount an AP-7602 Access Point to a wall surface (no telco box):
1. Place the mounting bracket against the wall.
2. Mark the screw hole locations.
CAUTION Ensure AC power is supplied to the Power Injector using
an AC cable with an appropriate ground connection
approved for the country of operation.
NOTE Before mounting and installing the AP-7602, obtain the
unit’s default IP address from the backside of the unit. This
default IP address is needed when connecting to the
Access Point.
NOTE When pre-drilling a hole the recommended hole size is 4mm
(0.16in.).
!