User's Manual

Installation Guide 13
3. At each point, drill a hole in the wall and attach the mounting bracket.
4. Cable the AP-7602 using either the Power Injector solution, an approved AP-7602
power supply or a POE enabled switch.
For Power Injector installations:
a. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the Power Injector
Data & Power Out connector and the AP-7602’s GE1/POE port.
b. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the network data
supply (host) and the Power Injector Data In connector.
c. Ensure the cable length from the Ethernet source (host) to the Power Injector and
AP-7602 does not exceed 100 meters (333 ft). The Power Injector has no On/Off
power switch. The Power Injector receives power as soon as AC power is applied.
For standard power adapter (non Power Injector) and line cord installations:
a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the
AP-7602’s GE1/POE port.
b. Connect the power supply line cords to the power adapter.
c. Attach the power adapter cable into the power connector on the AP-7602.
d. Attach the power supply line cord to a power supply.
5. Once cabled, snap the AP-7602 on the mounting plate