Specifications

The format for the ^BC instruction is:
^BCo,h,f,g,e,m
where
^BC = Code 128 Bar Code
o = Orientation
Default value: Current ^FW setting
Other values:
N = Normal
R = Rotated, 90 degrees clockwise
I = Inverted, 180 degrees
B = Read from Bottom Up, 270 degrees
h = Bar Code Height
Default value: Value set by ^BY
Other values: 1 dot to 9999 dots
f = Print Interpretation Line
Default value: Y = Yes
Other value: N=No
NOTE: Intrepretation line can be printed in
any available font by placing the instruction for the
font directly before the bar code instruction.
g = Print Interpretation Line Above Code
Default value: N=No
Other value: Y = Yes
NOTE: Default changes to Yes in UCC Case Mode
e = UCC Check Digit
Default value: N=No
Other value: Y = Yes
m = Mode
Default value: N = No mode selected
Other value: U = UCC Case Mode
(^FD or ^SN statement must contain 19
numeric digits (it can also contain valid alpha
characters). Subset C using FNC1 values is
automatically selected.