Specifications

The format for the ^SS instruction is:
^SSw,m,r,l,m2,r2,a.b.c
where
^SS = Set Media Sensors
w = 3-Digit Value for the Web (000 to 100)
Default value: Value shown on the media sensor
profile or configuration label.
m = 3-Digit Value for the Media (000 to 100)
Default value: Value shown on the media sensor
profile or configuration label.
r = 3-Digit Value for the Ribbon (000 to 100)
Default value: Value shown on the media sensor
profile or configuration label.
l = 4-Digit Value for the Label Length in Dots
(0001 to 9999)
Default value: The value calculated in the “Cali-
bration” process. (See the configuration label).
m2 = 3-Digit Value for Intensity of Media LED
(000 to 100)
Default value: The value calculated in the “Cali-
bration” process. (See the configuration label).
r2 = 3-Digit Value for Intensity of Ribbon LED
(000 to 100)
Default value: The value calculated in the “Cali-
bration” process. (See the configuration label)
Effective for Version 14.5.3
a = 3-Digit Value for Mark Sensing (000 to 100)
b = 3-Digit Value for Mark Media Sensing (000 to 100)
c = 3-Digit Value for Mark LED Sensing (000 to 100)
NOTE: The ‘m2’ and ‘r2’ values have no effect in Stripe Printers.