Reference Guide
Table Of Contents
- Contents
- About This Document
- Getting Started
- 123Scan and Software Tools
- Data Capture
- Maintenance, Troubleshooting, and Technical Specifications
- Radio Communications
- Introduction
- Setting Parameters
- Radio Communications Parameter Defaults
- Wireless Beeper Definitions
- Radio Communication Host Types
- Bluetooth Friendly Name
- Wi-Fi Friendly Mode
- Wi-Fi Friendly Channel Exclusion (continued)
- Radio Output Power
- Bluetooth Radio State
- HID Host Parameters
- Auto-Reconnect Feature
- Out of Range Indicator
- Beep on Insertion
- Digital Scanner(s) To Cradle Support
- Batch Mode
- Persistent Batch Storage
- Page Button
- Page Options
- Cradle Bluetooth Operation Mode
- Bluetooth Security
- Bluetooth Radio, Linking, and Batch Operation
- User Preferences
- Introduction
- Scanning Sequence Examples
- Errors While Scanning
- User Preferences Parameter Defaults
- Parameters
- Default Parameters
- Parameter Barcode Scanning
- Beep After Good Decode
- Beep on
- Direct Decode Indicator
- Beeper Volume
- Beeper Tone
- Beeper Duration
- Suppress Power Up Beeps
- Decode Pager Motor
- Decode Pager Motor Duration
- Night Mode (CS6080-HC Only)
- Haptic Feedback (Vibrate) on Button Touch
- Click on Button Touch
- Lamp Mode
- Low Power Mode
- Time Delay to Low Power Mode
- Timeout to Low Power Mode from Auto Aim
- Battery Preservation Mode
- Hand-Held Trigger Mode
- Hands-Free Mode
- Hand-Held Decode Aiming Pattern
- Hands-Free Decode Aiming Pattern
- Picklist Mode
- FIPS Mode
- Continuous Barcode Read
- Unique Barcode Reporting
- Decode Session Timeout
- Hands-free Decode Session Timeout
- Timeout Between Decodes, Same Symbol
- Timeout Between Decodes, Different Symbols
- Triggered Timeout, Same Symbol
- Decode Mirror Images (Data Matrix Only)
- Mobile Phone/Display Mode
- PDF Prioritization
- PDF Prioritization Timeout
- Presentation Mode Field of View
- Decoding Illumination
- Illumination Brightness
- Motion Tolerance (Hand-Held Trigger Modes Only)
- Add an Enter Key
- Transmit Code ID Character
- Prefix/Suffix Values
- Scan Data Transmission Format
- FN1 Substitution Values
- Transmit “No Read” Message
- Unsolicited Heartbeat Interval
- securPharm Decoding
- securPharm Output Formatting
- Programmable Button for Single Press
- Imaging Preferences
- Introduction
- Scanning Sequence Examples
- Errors While Scanning
- Imaging Preferences Parameter Defaults
- Imaging Preferences
- Operational Modes
- Image Capture Illumination
- Image Capture Autoexposure
- Fixed Exposure
- Fixed Gain
- Gain/Exposure Priority for Snapshot Mode
- Snapshot Mode Timeout
- Snapshot Aiming Pattern
- Silence Operational Mode Changes
- Image Cropping
- Crop to Pixel Addresses
- Image Size (Number of Pixels)
- Image Brightness (Target White)
- JPEG Image Options
- JPEG Target File Size
- JPEG Quality and Size Value
- Image Enhancement
- Image File Format Selector
- Image Rotation
- Bits Per Pixel
- Signature Capture
- Signature Capture File Format Selector
- Signature Capture Bits Per Pixel
- Signature Capture Width
- Signature Capture Height
- Signature Capture JPEG Quality
- Video View Finder (Corded Mode Only)
- Video View Finder Image Size
- USB Interface
- Introduction
- Connecting a USB Interface
- USB Parameter Defaults
- USB Host Parameters
- USB Device Type
- Symbol Native API (SNAPI) Status Handshaking
- USB Keystroke Delay
- USB CAPS Lock Override
- USB Ignore Unknown Characters
- USB Convert Unknown to Code 39
- Emulate Keypad
- Emulate Keypad with Leading Zero
- Quick Keypad Emulation
- USB Keyboard FN 1 Substitution
- Function Key Mapping
- Simulated Caps Lock
- Convert Case
- USB Static CDC
- Optional USB Parameters
- ASCII Character Sets for USB
- SSI Interface
- Symbologies
- Introduction
- Scanning Sequence Examples
- Errors While Scanning
- Symbology Parameter Defaults
- Enable/Disable All Code Types
- UPC/EAN
- Enable/Disable UPC-A
- Enable/Disable UPC-E
- Enable/Disable UPC-E1
- Enable/Disable EAN-8/JAN-8
- Enable/Disable EAN-13/JAN-13
- Enable/Disable Bookland EAN
- Decode UPC/EAN/JAN Supplementals
- User-Programmable Supplementals
- UPC/EAN/JAN Supplemental Redundancy
- UPC/EAN/JAN Supplemental AIM ID Format
- UPC Reduced Quiet Zone
- Transmit UPC-A Check Digit
- Transmit UPC-E Check Digit
- Transmit UPC-E1 Check Digit
- UPC-A Preamble
- UPC-E Preamble
- UPC-E1 Preamble
- Convert UPC-E to UPC-A
- Convert UPC-E1 to UPC-A
- EAN-8/JAN-8 Extend
- Bookland ISBN Format
- UCC Coupon Extended Code
- Coupon Report
- ISSN EAN
- Code 128
- Code 39
- Code 93
- Code 11
- Interleaved 2 of 5 (ITF)
- Discrete 2 of 5 (DTF)
- Codabar (NW - 7)
- MSI
- Chinese 2 of 5
- Matrix 2 of 5
- Korean 3 of 5
- Inverse 1D
- GS1 DataBar
- Composite
- 2D Symbologies
- Postal Codes
- Symbology-Specific Security Levels
- Report Version
- Macro PDF Features
- Digimarc Barcode
- Data Formatting: ADF, MDF, Preferred Symbol
- OCR Programming
- Driver’s License Set Up
- Standard Parameter Defaults
- Country Codes
- Country Code Pages
- CKJ Decode Control
- Programming Reference
- Sample Barcodes
- Numeric Barcodes
- Alphanumeric Barcodes
- ASCII Character Sets
- Communication Protocol Functionality
- Signature Capture Code
- Non-Parameter Attributes
- Scan Speed Analytics
- Upgrading Over Bluetooth Without A Cradle
- Index
Maintenance, Troubleshooting, and Technical Specifications
33
Dump Scanner Parameters
To debug a scanner issue, scan the following barcode with the scanner connected in USB HID keyboard
mode to Microsoft
®
Windows Notepad or Wordpad. This outputs all the scanner's asset tracking
information and parameter settings to a text document.
See the parameter numbers in <em_Emphasis><bl_blue>Appendix A, Standard Parameter Defaults to
interpret the parameter/attribute numbers in the output.
Digital scanner
emits five
long low beeps after a
barcode is decoded.
Conversion or format error was
detected.
The scanner conversion
parameters are not properly
configured.
Ensure the scanner conversion parameters
are properly configured.
Conversion or format error was
detected.
An ADF rule was set up with
characters that can't be sent for the
host selected.
Change the ADF rule, or change to a host that
can support the ADF rule.
Conversion or format error was
detected.
A barcode was scanned with
characters that can't be sent for
that host.
Change the barcode, or change to a host that
can support the barcode.
Digital scanner LED blinks
even if the pairing request
was canceled from remote
iOS/Android
™
device.
If pass key entry is canceled from
the tablet/phone, the digital
scanner remains in the pass key
entry mode for 30 seconds before
timing out.
To exit pass key entry mode scan
<bl_blue><em_Emphasis>Cancel on page
H-1 or scan any other barcode.
Table 8-1 Troubleshooting (Continued)
Problem Possible Causes Possible Solutions
note If after performing these checks the digital scanner still experiences problems, contact the distributor or
call support.
note Use 123Scan if available as an alternative to using this feature. 123Scan is the preferable method for
outputting scanner information.
note For proper formatting, it may be necessary to first scan <bl_blue><em_Emphasis><DATA> <SUFFIX 1>
(1) on page 6-40.
Dump Scanner Parameters
guide-user-color-8.5x11.book Page 33 Monday, June 1, 2020 5:43 PM
Draft v 10