OCR Programming
354
OCR Redundancy
Parameter # 1770 (SSI # F8h 06h EAh)
This option adjusts the number of times to decode an OCR text string before transmission. There are three
levels of OCR decode redundancy. There is an inverse relationship between the redundancy level and
OCR decoding aggressiveness. Increasing the level of the redundancy can reduce OCR scanning
aggressiveness, so select only the level of redundancy necessary.
OCR Redundancy Level 1: This default setting allows the digital scanner to operate in its most
aggressive state while providing sufficient accuracy in decoding most in-spec OCR text strings.
OCR Redundancy Level 2: This setting eliminates most misdecodes while maintaining reasonable
aggressiveness.
OCR Redundancy Level 3: Select this option with greater redundancy requirements if OCR
Redundancy Level 2 fails to eliminate misdecodes.
*OCR Redundancy Level 1
(1)
OCR Redundancy Level 2
(2)
OCR Redundancy Level 3
(3)
guide-user-color-8.5x11.book Page 354 Monday, June 1, 2020 5:43 PM