Specifications

ZPL Commands
^B7
34
45541L-004 Rev. A ZPL II Programming Guide 9/15/06
Special Considerations for ^BY When Using PDF417
When used with ^B7, the parameters for the ^BY command are:
w
= module width (in dots)
Accepted Values:
2 to 10
Default Value: 2
r
= ratio
Fixed Value:
3 (ratio has no effect on PDF417)
h
= height of bars (in dots)
Accepted Values:
1 to 32000
Default Value: 10
PDF417 uses this only when row height is not specified in the ^B7 h parameter.
Special Considerations for ^FD When Using PDF417
The character set sent to the printer with the ^FD command includes the full ASCII set, except
for those characters with special meaning to the printer.
See Zebra Code Page 850 on page 342, ^CC ~CC on page 107, and ^CT ~CT on page 118.
CR and LF are also valid characters for all
^FD statements. This scheme is used:
\& = carriage return/line feed
\\ = backslash (\)
^CI13 must be selected to print a backslash (\).