Specification
(1)
Dimensions (Width Depth Height)
MC 80
DX
camera body............................................................................................130 85 150 mm
35 mm Mot
DX
film cassette.......................................................................................115 40 65 mm
D4 databack...............................................................................................................112 45 53 mm
M 4 5” large-frame attachment...........................................................................175 175 245 mm
MC 80
DX
control console.......................................................................................220 350 105 mm
Keyboard .................................................................................................................280 139 25 mm
(2)
Weights
MC 80
DX
camera body.................................................................................................................1.4 kg
35 mm Mot
DX
film cassette........................................................................................................0.25 kg
D4 databack................................................................................................................................0.05 kg
M 4 5” large-frame attachment................................................................................................1.85 kg
MC 80
DX
control console............................................................................................................2.55 kg
Keyboard ......................................................................................................................................0.4 kg
(3)
Environmental Requirements
Storage and shipment (packed):
Permissible ambient temperature....................................................................................... -10 to +60 °C
Permissible relative humidity............................................................................. 20 % to 85 % at +35 °C
Atmospheric pressure............................................................................................. 800 hPa to 1060 hPa
Operation:
Permissible ambient temperature.......................................................................................... 0 to +45 °C
Permissible relative humidity............................................................................. 20 % to 85 % at +35 °C
Atmospheric pressure............................................................................................. 800 hPa to 1060 hPa
Pollution degree................................................................................................................................... 2
(4)
Operating data
Installation ......................................................................................................................in closed rooms
Protection class...................................................................................................................................... I
Type of enclosure............................................................................................................................IP 20
Electric safety......................................................................conforming to DIN EN 61010-1 (IEC 1010-1)
....................................................................................................... allowing for CSA and UL regulations
Overvoltage category.............................................................................................................................II
Radio interference suppression................................................................conforming to EN 55011 class B
Noise immunity ..............................................................................................conforming to EN 50082-2
Line voltage......................................................................................100...240 V, no conversion required
Permissible line voltage fluctuation...............................................................................................
±10 %
Line frequency...........................................................................................................................50/60 Hz
Power consumption.............................................................................................................about 25 VA
Line input fuse .........................................................................for 100...240 V: slow-blow 2.5 A / 250 V
Clock function error .................................................................................... < ±2 minutes/month (25 °C)