Service manual
PV151 1-1 PROJO
CAUTIONS WHEN CONNECTING / DISCONNECTING THE HV CONNECTOR
Perform the following when the HV connector (anode
connector) is removed or inserted for CPT replacement,
etc.
During Removal
1. Roll out silicon cover from FBT’s contact area slowly.
2. While turning the connector about 90 degrees following the arrow
(0 position). Push the connector slightly toward the case. (Fig. A)
During Insertion
1. Please refer to direction for insertion as shown in Fig. B (L position).
Insert connector until “CLICK” sound is heard.
2. Make sure the connector is pressed right in, so that it has a good
contact with the spring.
3. Confirm the contact by pulling the connector slightly. (Don’t pull
hard because it may damage the connector).
4. Cover the high voltage output by carefully pushing silicon boot
onto it. (Don’t turn the connector).
Note: Make sure the silicon boot is covering the high
voltage output.
FIG. A
PUSH
PUSH
HV Cable
FlybackTAB
POSITION
FIG. B
Flyback
HV Cable &
Boot Assembly
LESS THAN 1mm
DEFLECTION
P.W.B
FBT
ANODE
CONNECTOR
3. Remove the connector slowly by pulling it away from the case.