Service manual
PV151 1-2 PROJO
TECHNICAL CAUTIONS
High Voltage limiter circuit check
1. Turn off TV and connect jig as shown in Figure 2.
Adjust jig fully counter clockwise for minimun
resistance.
2. Set the AC input to 120V AC and turn on TV.
3. Confirm test pattern on CRT is a usable picture, then
slowly adjust jig until the picture disappears and TV
shuts down.
4. When the limiter circuit is operating properly, Voltage
will be less than 36.5kV at 0.6mA when TV shuts down.
5. Turn off set immediately after checking circuit operations.
6. Unplug set for one minute to reset shutdown circuit.
Remove jig and voltmeter.
Figure 2. Deflection/Power PCB
SECTION 1
High Voltage
Connector
FBT
)
(TH01
Defelection
P.W.B.
Chassis Ground
High Impedance
H.V. Meter
FBT
TP91
RH80
POWER/DEFLECTION PWB
50K Ohm VR
JIG
Remove 80 and connect 50K Ohm jig as shown
RH
RH44