2.2.1.10. FLOATING POINT INDICATOR
Floating Point is a real number representation method that can be
adapted to the order of magnitude of the value represented.
In this particular case, enabling a box as “Floating Point indicator”,
integrators can select the type of data represented on the display,
choosing among:
Temperature (ºC) Æ Range [-273ºC….670,760ºC]
Wind Speed (m/s)
Æ Range [0m/s….670,760m/s]
Humidity (%)
Æ Range [0%….670,760%]
Luminosity (lux)
Æ Range [0lux…670,760lux]
Other (no simbol)
Æ Range [-670,760……670,760]
Note I:
Depending on the data type selected a different unit
symbol will be shown.
2.2.1.11. SECURITY CONTROL
“Home” and “Home II” individual boxes may also be protected
against unauthorised access.
In this case, the Panel will not send any binary data to the BUS unless
the correct password is entered
ICON Æ An icon can be associated to the display box. (See Annexe
II).
INDICATOR Æ
By activating this parameter, an status indicator will
be inserted between both buttons:
ON/OFF
0/1
2.2.1.12. PRESENCE SIMULATION
This function is designed to simulate presence in a house, once the
devices on the KNX installation have been correctly parameterized,
two new Communication Objects become active:
¾ Presence Simulation (1 bit): Enable/Disable the function
¾ Simulation Channel (1 bit):
Generate the ON/OFF