Instruction manual

17
* The aperture ring must not be adjusted while the depth of field pre-
view is being depressed.
* If exposure measurements are taken with the depth of field preview
lever depressed, when using a finder with built-in exposure meter, the
shutter speed setting indicated will cause over-exposure. This is
because proper exposures are obtained with exposure measure-
ments made at the full aperture.
A. The lens is focused on the subject, by rotating the focusing ring in
either direction, while checking the effect on the micro-prism / split-
image range finder spot in the center of the focusing screen (stan-
dard type).
B. The central split-image spot splits the image into two, with the
upper and lower halves separated horizontally when the lens is out of
focus. When in focus, however, the two halves will coincide with the
displacement disappearing.The micro-prism ring surrounding the
central spot can also be used for checking the sharpness of the
focused image, since the image will glitter when the lens is not
focused. The surrounding full-area matte surface can also be used for
checking overall image sharpness.
A. Distance scales on the Zenzanon PS lenses can be used for focus-
ing at the required distance or finding the distance actually focused.
Simply rotate the focusing ring and set the required distance oppo-
site the orange-colored index, which will adjust the lens for the
required distance.
18. Setting the Aperture (con’t)
19. Focusing Adjustments
20. Distance Scale and Depth of Field Scale