Instruction manual
23
8. Explanation of Airdolphin Operations
23
During operation, the indicator LED on the body of
the Airdolphin can be used to check the operating
status of the system.
The indicator LED can light in solid or flashing red,
green and orange (red and green).
Indicator LED
Mode Indicator Status Status Cause Operation
Power Assist
Mode
Solid Orange
Power Assist rotates
t h e A i r d o l p h i n at
80rpm in 10-second
every minute
No wind for 1 minute Operating Normally
Normal Mode 1
250rpm–
1000rpm
Solid Green
Generating electricity
Wind speed - 10m/s
Rotor rotating at 250–
1000rpm
Operating Normally
Normal Mode 2
(1000rpm)
Flashing Green
Generating electricity
Wind speed 10 - 20m/s
Rotor rotating at 1000 rpm Operating Normally
Normal Mode 3
(600rpm)
Solid Red Generating electricity
Wind speed 20m/s -
a. Battery fully charged
(voltage exceeds 59.2V)
b. At around 20m/s or
more of wind speed
Operating Normally
Stop Mode
Flashing Red and
Green
Rtating slowly or stop
Power assist stop
a. Over voltage (battery
voltage exceeded 72V)
b.
Generator ambient tem-
perature exceeded 90°C
a. System returns
to normal mode
if the battery volt-
age drops below
53.2V.
b. System returns
to normal mode if
generator motor
ambi-ent tempera-
ture drops below
60°C
Restart
(Same as start
mode)
Solid green for 10
seconds, ashing
orange for 5 sec-
onds, solid red for
90 seconds
Power On/Off
System started
in normal mode
Operating Status List